Body fat percentage


The body fat percentage of a human or other living being is the total mass of fat divided by total body mass, multiplied by 100; body fat includes essential body fat and storage body fat. Essential body fat is necessary to maintain life and reproductive functions. The percentage of essential body fat for women is greater than that for men, due to the demands of childbearing and other hormonal functions. Storage body fat consists of fat accumulation in adipose tissue, part of which protects internal organs in the chest and abdomen. A number of methods are available for determining body fat percentage, such as measurement with calipers or through the use of bioelectrical impedance analysis.
The body fat percentage is a measure of fitness level, since it is the only body measurement which directly calculates a person's relative body composition without regard to height or weight. The widely used body mass index provides a measure that allows the comparison of the adiposity of individuals of different heights and weights. While BMI largely increases as adiposity increases, due to differences in body composition, other indicators of body fat give more accurate results; for example, individuals with greater muscle mass or larger bones will have higher BMIs. As such, BMI is a useful indicator of overall fitness for a large group of people, but a poor tool for determining the health of an individual.

Typical body fat amounts

, the percentage of body fat in an individual varies according to sex and age. Various theoretical approaches exist on the relationships between body fat percentage, health, athletic capacity, etc. Different authorities have consequently developed different recommendations for ideal body fat percentages.
This graph from the National Health and Nutrition Examination Survey in the United States charts the average body fat percentages of Americans from samples from 1999–2004:
In males, mean percentage body fat ranged from 22.9% at age 16–19 years to 30.9% at age 60–79 years. In females, mean percentage body fat ranged from 32.0% at age 8–11 years to 42.4% at age 60–79 years.
The table below from the American Council on Exercise shows how average percentages differ according to the specified groups and categories:
DescriptionWomenMen
Essential fat10–13%2–5%
Athletes14–20%6–13%
Fitness21–24%14–17%
Average25–31%18–24%
Obese32%+25%+

Essential fat is the level at which physical and physiological health would be negatively affected, and below which death is certain. Controversy exists as to whether a particular body fat percentage is better for one's health; athletic performance may also be affected. The leanest athletes typically compete at levels of about 6-13% for men or 14–20% for women. Bodybuilders may compete at essential body fat range, in fact certified personal trainers will suggest them to keep that extremely low level of body fat only for the contest time. However it is unclear that such levels are ever actually attained since the means to measure such levels are, as noted below, lacking in principle and inaccurate, and 4–6% is generally considered a physiological minimum for human males.

Measurement techniques

Underwater weighing

Irrespective of the location from which they are obtained, the fat cells in humans are composed almost entirely of pure triglycerides with an average density of about 0.9 kilograms per litre. Most modern body composition laboratories today use the value of 1.1 kilograms per litre for the density of the "fat free mass", a theoretical tissue composed of 72% water, 21% protein and 7% mineral by weight.
With a well engineered weighing system, body density can be determined with great accuracy by completely submerging a person in water and calculating the volume of the displaced water from the weight of the displaced water. A correction is made for the buoyancy of air in the lungs and other gases in the body spaces. If there were no errors whatsoever in measuring body density, the uncertainty in fat estimation would be about ± 3.8% of the body weight, primarily because of normal variability in body constituents.

Whole-body air displacement plethysmography

Whole-body air displacement plethysmography is a recognised and scientifically validated densitometric method to measure human body fat percentage. ADP uses the same principles as the gold-standard method of underwater weighing, but representing a densitometric method that is based on air displacement rather than on water immersion. Air-displacement plethysmography offers several advantages over established reference methods, including a quick, comfortable, automated, noninvasive, and safe measurement process, and accommodation of various subject types. However, its accuracy declines at the extremes of body fat percentages, tending to slightly understate the percent body fat in overweight and obese persons, and to overstate to a much larger degree the percent body fat in very lean subjects.

Near-infrared interactance

A beam of infra-red light is transmitted into a biceps. The light is reflected from the underlying muscle and absorbed by the fat. The method is safe, noninvasive, rapid and easy to use.

Dual energy X-ray absorptiometry

Dual energy X-ray absorptiometry, or DXA, is a newer method for estimating body fat percentage, and determining body composition and bone mineral density.
X-rays of two different energies are used to scan the body, one of which is absorbed more strongly by fat than the other. A computer can subtract one image from the other, and the difference indicates the amount of fat relative to other tissues at each point. A sum over the entire image enables calculation of the overall body composition.

Expansions

There are several more complicated procedures that more accurately determine body fat percentage. Some, referred to as multicompartment models, can include DXA measurement of bone, plus independent measures of body water and body volume. Various other components may be independently measured, such as total body potassium.
In-vivo neutron activation can quantify all the elements of the body and use mathematical relations among the measured elements in the different components of the body to develop simultaneous equations to estimate total body composition, including body fat.

Body average density measurement

Prior to the adoption of DXA, the most accurate method of estimating body fat percentage was to measure that person's average density and apply a formula to convert that to body fat percentage.
Since fat tissue has a lower density than muscles and bones, it is possible
to estimate the fat content. This estimate is distorted by the fact that muscles and bones have different densities: for a person with a more-than-average amount of bone mass, the estimate will be too low. However, this method gives highly reproducible results for individual persons, unlike the methods discussed below, which can have an uncertainty of 10%, or more. The body fat percentage is commonly calculated from one of two formulas :
The bioelectrical impedance analysis method is a lower-cost but less accurate way to estimate body fat percentage. The general principle behind BIA: two or more conductors are attached to a person's body and a small electric current is sent through the body. The resistance between the conductors will provide a measure of body fat between a pair of electrodes, since the resistance to electricity varies between adipose, muscular and skeletal tissue. Fat-free mass is a good conductor as it contains a large amount of water and electrolytes, while fat is anhydrous and a poor conductor of electric current. Factors that affect the accuracy and precision of this method include instrumentation, subject factors, technician skill, and the prediction equation formulated to estimate the fat-free mass.
Each foot may be placed on an electrode, with the current sent up one leg, across the abdomen and down the other leg. Alternatively, an electrode may be held in each hand; calculation of fat percentage uses the weight, so that must be measured with scales and entered by the user. The two methods may give different percentages, without being inconsistent, as they measure fat in different parts of the body. More sophisticated instruments for domestic use are available with electrodes for both feet and hands.
There is little scope for technician error as such, but factors such as eating, drinking and exercising must be controlled since hydration level is an important source of error in determining the flow of the electric current to estimate body fat. The instructions for use of instruments typically recommended not making measurements soon after drinking or eating or exercising, or when dehydrated. Instruments require details such as sex and age to be entered, and use formulae taking these into account; for example, men and women store fat differently around the abdomen and thigh region.
Different BIA analysers may vary. Population-specific equations are available for some instruments, which are only reliable for specific ethnic groups, populations, and conditions. Population-specific equations may not be appropriate for individuals outside of specific groups.

Anthropometric methods

There exist various anthropometric methods for estimating body fat. The term anthropometric refers to measurements made of various parameters of the human body, such as circumferences of various body parts or thicknesses of skinfolds. Most of these methods are based on a statistical model. Some measurements are selected, and are applied to a population sample. For each individual in the sample, the method's measurements are recorded, and that individual's body density is also recorded, being determined by, for instance, under-water weighing, in combination with a multi-compartment body density model. From this data, a formula relating the body measurements to density is developed.
Because most anthropometric formulas such as the Durnin-Womersley skinfold method, the Jackson-Pollock skinfold method, and the US Navy circumference method, actually estimate body density, not body fat percentage, the body fat percentage is obtained by applying a second formula, such as the Siri or Brozek described in the above section on density. Consequently, the body fat percentage calculated from skin folds or other anthropometric methods carries the cumulative error from the application of two separate statistical models.
These methods are therefore inferior to a direct measurement of body density and the application of just one formula to estimate body fat percentage. One way to regard these methods is that they trade accuracy for convenience, since it is much more convenient to take a few body measurements than to submerge individuals in water.
The chief problem with all statistically derived formulas is that in order to be widely applicable, they must be based on a broad sample of individuals. Yet, that breadth makes them inherently inaccurate. The ideal statistical estimation method for an individual is based on a sample of similar individuals. For instance, a skinfold based body density formula developed from a sample of male collegiate rowers is likely to be much more accurate for estimating the body density of a male collegiate rower than a method developed using a sample of the general population, because the sample is narrowed down by age, sex, physical fitness level, type of sport, and lifestyle factors. On the other hand, such a formula is unsuitable for general use.

Skinfold methods

The skinfold estimation methods are based on a skinfold test, also known as a pinch test, whereby a pinch of skin is precisely measured by calipers, also known as a plicometer, at several standardized points on the body to determine the subcutaneous fat layer thickness. These measurements are converted to an estimated body fat percentage by an equation. Some formulas require as few as three measurements, others as many as seven. The accuracy of these estimates is more dependent on a person's unique body fat distribution than on the number of sites measured. As well, it is of utmost importance to test in a precise location with a fixed pressure. Although it may not give an accurate reading of real body fat percentage, it is a reliable measure of body composition change over a period of time, provided the test is carried out by the same person with the same technique.
Skinfold-based body fat estimation is sensitive to the type of caliper used, and technique. This method also only measures one type of fat: subcutaneous adipose tissue. Two individuals might have nearly identical measurements at all of the skin fold sites, yet differ greatly in their body fat levels due to differences in other body fat deposits such as visceral adipose tissue: fat in the abdominal cavity. Some models partially address this problem by including age as a variable in the statistics and the resulting formula. Older individuals are found to have a lower body density for the same skinfold measurements, which is assumed to signify a higher body fat percentage. However, older, highly athletic individuals might not fit this assumption, causing the formulas to underestimate their body density.

Ultrasound

Ultrasound is used extensively to measure tissue structure and has proven to be an accurate technique to measure subcutaneous fat thickness. A-mode and B-mode ultrasound systems are now used and both rely on using tabulated values of tissue sound speed and automated signal analysis to determine fat thickness. By making thickness measurements at multiple sites on the body you can calculate the estimated body fat percentage. Ultrasound techniques can also be used to directly measure muscle thickness and quantify intramuscular fat. Ultrasound equipment is expensive, and not cost-effective solely for body fat measurement, but where equipment is available, as in hospitals, the extra cost for the capability to measure body fat is minimal.

Height and circumference methods

There also exist formulas for estimating body fat percentage from an individual's weight and girth measurements. For example, the U.S. Navy circumference method compares abdomen or waist and hips measurements to neck measurement and height and other sites claim to estimate one's body fat percentage by a conversion from the body mass index. In the U.S. Navy the method is known as the "rope and choke." There is limited information, however, on the validity of the "rope and choke" method because of its universal acceptance as inaccurate and easily falsified.
The U.S. Army and U.S. Marine Corps also rely on the height and circumference method. For males, they measure the neck and waist just above the navel. Females are measured around the hips, waist, and neck. These measurements are then looked up in published tables, with the individual's height as an additional parameter. This method is used because it is a cheap and convenient way to implement a body fat test throughout an entire service.
Methods using circumference have little acceptance outside the Department of Defense due to their negative reputation in comparison to other methods. The method's accuracy becomes an issue when comparing people with different body compositions, those with larger necks artificially generate lower body fat percentage calculations than those with smaller necks.

From BMI

Body fat can be estimated from body mass index, a person's mass in kilograms divided by the square of the height in meters; if weight is measured in pounds and height in inches, the result can be converted to BMI by multiplying by 703. There are a number of proposed formulae that relate body fat to BMI. These formulae are based on work by researchers published in peer-reviewed journals, but their correlation with body fat are only estimates; body fat cannot be deduced accurately from BMI.
Body fat may be estimated from the body mass index by formulae derived by Deurenberg and co-workers. When making calculations, the relationship between densitometrically determined body fat percentage and BMI must take age and sex into account. Internal and external cross-validation of the prediction formulas showed that they gave valid estimates of body fat in males and females at all ages. In obese subjects, however, the prediction formulas slightly overestimated the BF%. The prediction error is comparable to the prediction error obtained with other methods of estimating BF%, such as skinfold thickness measurements and bioelectrical impedance. The formula for children is different; the relationship between BMI and BF% in children was found to differ from that in adults due to the height-related increase in BMI in children aged 15 years and younger.
However – contrary to the aforementioned internal and external cross-validation –, these formulae definitely proved unusable at least for adults and are presented here illustratively only.
Still, the following formula designed for adults proved to be much more accurate at least for adults:
Other indices may be used; the body adiposity index was said by its developers to give a direct estimate of body fat percentage, but statistical studies found this not to be so.