The Catawba Nuclear Station is a nuclear power plant located on a peninsula, called "Concord Peninsula", that reaches out into Lake Wylie, in York, South Carolina, USA. Catawba utilizes a pair of Westinghouse four-loop pressurized water reactors. As a part of the Megatons to Megawatts Program Catawba was one of the plants that received and tested 4 fuel assemblies containing MOX fuel with the plutonium supplied from old weapons programs. Because concerns of nuclear proliferation are greater with fuel containing plutonium, special precautions and added security were used around the new fuel. The four test assemblies did not perform as expected and at present those plans are shelved.
History
In 2005, Catawba Nuclear Station's Unit 1 was selected to test four fuel assemblies containing mixed oxide fuel, incorporating 140 kg of plutonium supplied from recycled nuclear weapons material. The MOX fuel pellets were supplied by the Cadarache reprocessing facilitiy, and placed into fuel assemblies at the Melox facility, both in France. This test was part of the "Megatons to Megawatts" program, which was part of the Plutonium Management and Disposition Agreement between the United States and Russia.
Plant design
The Catawba Nuclear Station uses ice condensers as part of its emergency containment systems. A nuclear plant ice condenser is a passive, static heat sink that relies on large quantities of ice to mitigate severe accidents. Ice condensers are designed to limit pressure in the event of an accidental steam release. This design allows smaller containment structures and reduced material requirements.
The Nuclear Regulatory Commission defines two emergency planning zones around nuclear power plants: a plume exposure pathway zone with a radius of, concerned primarily with exposure to, and inhalation of, airborne radioactive contamination, and an ingestion pathway zone of about, concerned primarily with ingestion of food and liquid contaminated by radioactivity. The 2010 population within of Catawba was 213,407, an increase of 53.3 percent in a decade, according to an analysis of the 2010 United States Census. The 2010 population within was 2,559,394, an increase of 25.0 percent since 2000. Cities within 50 miles include Charlotte, North Carolina.
Seismic risk
In 2010, the NRC estimated the risk each year of an earthquake intense enough to cause core damage to the reactor at Catawba was 1 in 27,027.
More than 100 gallons of water contaminated with radioactive tritium was released. However, the levels of tritium were less than one half the EPA limit for tritium and the leak was contained before it reached ground water.
After a 1-month standard inspection, the Nuclear Regulatory Commission found that Catawba Nuclear Station staff had failed to take preventive maintenance measures after an electrical component in one of the emergency diesel generators had failed a routine inspection test. As a result, the NRC increased oversight of the plant until the issue was corrected. This incident was concluded to be of low to moderate safety significance.