Darcy–Weisbach equation


In fluid dynamics, the Darcy–Weisbach equation is an empirical equation, which relates the head loss, or pressure loss, due to friction along a given length of pipe to the average velocity of the fluid flow for an incompressible fluid. The equation is named after Henry Darcy and Julius Weisbach.
The Darcy–Weisbach equation contains a dimensionless friction factor, known as the Darcy friction factor. This is also variously called the Darcy–Weisbach friction factor, friction factor, resistance coefficient, or flow coefficient.

Pressure-loss form

In a cylindrical pipe of uniform diameter, flowing full, the pressure loss due to viscous effects is proportional to length and can be characterized by the Darcy–Weisbach equation:
where the pressure loss per unit length is a function of:
For laminar flow in a circular pipe of diameter, the friction factor is inversely proportional to the Reynolds number alone which itself can be expressed in terms of easily measured or published physical quantities. Making this substitution the Darcy–Weisbach equation is rewritten as
where
Note that this laminar form of Darcy–Weisbach is equivalent to the Hagen–Poiseuille equation, which is analytically derived from the Navier–Stokes equations.

Head-loss form

The head loss expresses the pressure loss due to friction in terms of the equivalent height of a column of the working fluid, so the pressure drop is
where
It is useful to present head loss per length of pipe :
where is the pipe length.
Therefore, the Darcy–Weisbach equation can also be written in terms of head loss:

In terms of volumetric flow

The relationship between mean flow velocity and volumetric flow rate is
where:
In a full-flowing, circular pipe of diameter,
Then the Darcy–Weisbach equation in terms of is

Shear-stress form

The mean wall shear stress in a pipe or open channel is expressed in terms of the Darcy–Weisbach friction factor as
The wall shear stress has the SI unit of pascals.

Darcy friction factor

The friction factor is not a constant: it depends on such things as the characteristics of the pipe, the characteristics of the fluid, and the velocity of the fluid flow. It has been measured to high accuracy within certain flow regimes and may be evaluated by the use of various empirical relations, or it may be read from published charts. These charts are often referred to as Moody diagrams, after L. F. Moody, and hence the factor itself is sometimes erroneously called the Moody friction factor. It is also sometimes called the Blasius friction factor, after the approximate formula he proposed.
Figure 1 shows the value of as measured by experimenters for many different fluids, over a wide range of Reynolds numbers, and for pipes of various roughness heights. There are three broad regimes of fluid flow encountered in these data: laminar, critical, and turbulent.

Laminar regime

For laminar flows, it is a consequence of Poiseuille's law that
where is the Reynolds number
and where is the viscosity of the fluid and
is known as the kinematic viscosity. In this expression for Reynolds number, the characteristic length is taken to be the hydraulic diameter of the pipe, which, for a cylindrical pipe flowing full, equals the inside diameter. In Figures 1 and 2 of friction factor versus Reynolds number, the regime demonstrates laminar flow; the friction factor is well represented by the above equation.
In effect, the friction loss in the laminar regime is more accurately characterized as being proportional to flow velocity, rather than proportional to the square of that velocity: one could regard the Darcy–Weisbach equation as not truly applicable in the laminar flow regime.
In laminar flow, friction loss arises from the transfer of momentum from the fluid in the center of the flow to the pipe wall via the viscosity of the fluid; no vortices are present in the flow. Note that the friction loss is insensitive to the pipe roughness height : the flow velocity in the neighborhood of the pipe wall is zero.

Critical regime

For Reynolds numbers in the range, the flow is unsteady and varies from one section of the pipe to another. The flow involves the incipient formation of vortices; it is not well understood.

Turbulent regime

For Reynolds number greater than 4000, the flow is turbulent; the resistance to flow follows the Darcy–Weisbach equation: it is proportional to the square of the mean flow velocity. Over a domain of many orders of magnitude of , the friction factor varies less than one order of magnitude. Within the turbulent flow regime, the nature of the flow can be further divided into a regime where the pipe wall is effectively smooth, and one where its roughness height is salient.

Smooth-pipe regime

When the pipe surface is smooth, the friction factor's variation with Re can be modeled by the Kármán–Prandtl resistance equation for turbulent flow in smooth pipes with the parameters suitably adjusted
The numbers 1.930 and 0.537 are phenomenological; these specific values provide a fairly good fit to the data. The product can be considered, like the Reynolds number, to be a parameter of the flow: at fixed values of, the friction factor is also fixed.
In the Kármán–Prandtl resistance equation, can be expressed in closed form as an analytic function of through the use of the Lambert function:
In this flow regime, many small vortices are responsible for the transfer of momentum between the bulk of the fluid to the pipe wall. As the friction Reynolds number increases, the profile of the fluid velocity approaches the wall asymptotically, thereby transferring more momentum to the pipe wall, as modeled in Blasius boundary layer theory.

Rough-pipe regime

When the pipe surface's roughness height is significant, the friction factor departs from the smooth pipe curve, ultimately approaching an asymptotic value. In this regime, the resistance to flow varies according to the square of the mean flow velocity and is insensitive to Reynolds number. Here, it is useful to employ yet another dimensionless parameter of the flow, the roughness Reynolds number
where the roughness height is scaled to the pipe diameter.
It is illustrative to plot the roughness function :
Figure 3 shows versus for the rough pipe data of Nikuradse, Shockling, and Langelandsvik.
In this view, the data at different roughness ratio fall together when plotted against, demonstrating scaling in the variable. The following features are present:
A fit to these data in the transition from smooth pipe flow to rough pipe flow employs an exponential expression in that ensures proper behavior for :
This function shares the same values for its term in common with the Kármán–Prandtl resistance equation, plus one parameter 0.34 to fit the asymptotic behavior for along with one further parameter, 11, to govern the transition from smooth to rough flow. It is exhibited in Figure 3.
The Colebrook–White relation fits the friction factor with a function of the form
This relation has the correct behavior at extreme values of, as shown by the labeled curve in Figure 3: when is small, it is consistent with smooth pipe flow, when large, it is consistent with rough pipe flow. However its performance in the transitional domain overestimates the friction factor by a substantial margin. Colebrook acknowledges the discrepancy with Nikuradze's data but argues that his relation is consistent with the measurements on commercial pipes. Indeed, such pipes are very different from those carefully prepared by Nikuradse: their surfaces are characterized by many different roughness heights and random spatial distribution of roughness points, while those of Nikuradse have surfaces with uniform roughness height, with the points extremely closely packed.

Calculating the friction factor from its parametrization

For turbulent flow, methods for finding the friction factor include using a diagram, such as the Moody chart, or solving equations such as the Colebrook–White equation, or the Swamee–Jain equation. While the Colebrook–White relation is, in the general case, an iterative method, the Swamee–Jain equation allows to be found directly for full flow in a circular pipe.

Direct calculation when friction loss '''' is known

In typical engineering applications, there will be a set of given or known quantities. The acceleration of gravity and the kinematic viscosity of the fluid are known, as are the diameter of the pipe and its roughness height. If as well the head loss per unit length is a known quantity, then the friction factor can be calculated directly from the chosen fitting function. Solving the Darcy–Weisbach equation for,
we can now express :
Expressing the roughness Reynolds number,
we have the two parameters needed to substitute into the Colebrook–White relation, or any other function, for the friction factor, the flow velocity, and the volumetric flow rate.

Confusion with the Fanning friction factor

The Darcy–Weisbach friction factor is 4 times larger than the Fanning friction factor, so attention must be paid to note which one of these is meant in any "friction factor" chart or equation being used. Of the two, the Darcy–Weisbach factor is more commonly used by civil and mechanical engineers, and the Fanning factor by chemical engineers, but care should be taken to identify the correct factor regardless of the source of the chart or formula.
Note that
Most charts or tables indicate the type of friction factor, or at least provide the formula for the friction factor with laminar flow. If the formula for laminar flow is, it is the Fanning factor, and if the formula for laminar flow is, it is the Darcy–Weisbach factor.
Which friction factor is plotted in a Moody diagram may be determined by inspection if the publisher did not include the formula described above:
  1. Observe the value of the friction factor for laminar flow at a Reynolds number of 1000.
  2. If the value of the friction factor is 0.064, then the Darcy friction factor is plotted in the Moody diagram. Note that the nonzero digits in 0.064 are the numerator in the formula for the laminar Darcy friction factor:.
  3. If the value of the friction factor is 0.016, then the Fanning friction factor is plotted in the Moody diagram. Note that the nonzero digits in 0.016 are the numerator in the formula for the laminar Fanning friction factor:.
The procedure above is similar for any available Reynolds number that is an integer power of ten. It is not necessary to remember the value 1000 for this procedure—only that an integer power of ten is of interest for this purpose.

History

Historically this equation arose as a variant on the Prony equation; this variant was developed by Henry Darcy of France, and further refined into the form used today by Julius Weisbach of Saxony in 1845. Initially, data on the variation of with velocity was lacking, so the Darcy–Weisbach equation was outperformed at first by the empirical Prony equation in many cases. In later years it was eschewed in many special-case situations in favor of a variety of empirical equations valid only for certain flow regimes, notably the Hazen–Williams equation or the Manning equation, most of which were significantly easier to use in calculations. However, since the advent of the calculator, ease of calculation is no longer a major issue, and so the Darcy–Weisbach equation's generality has made it the preferred one.

Derivation by dimensional analysis

Away from the ends of the pipe, the characteristics of the flow are independent of the position along the pipe. The key quantities are then the pressure drop along the pipe per unit length,, and the volumetric flow rate. The flow rate can be converted to a mean flow velocity by dividing by the wetted area of the flow.
Pressure has dimensions of energy per unit volume, therefore the pressure drop between two points must be proportional to the dynamic pressure q. We also know that pressure must be proportional to the length of the pipe between the two points as the pressure drop per unit length is a constant. To turn the relationship into a proportionality coefficient of dimensionless quantity, we can divide by the hydraulic diameter of the pipe,, which is also constant along the pipe. Therefore,
The proportionality coefficient is the dimensionless "Darcy friction factor" or "flow coefficient". This dimensionless coefficient will be a combination of geometric factors such as, the Reynolds number and the relative roughness of the pipe.
Note that the dynamic pressure is not the kinetic energy of the fluid per unit volume, for the following reasons. Even in the case of laminar flow, where all the flow lines are parallel to the length of the pipe, the velocity of the fluid on the inner surface of the pipe is zero due to viscosity, and the velocity in the center of the pipe must therefore be larger than the average velocity obtained by dividing the volumetric flow rate by the wet area. The average kinetic energy then involves the root mean-square velocity, which always exceeds the mean velocity. In the case of turbulent flow, the fluid acquires random velocity components in all directions, including perpendicular to the length of the pipe, and thus turbulence contributes to the kinetic energy per unit volume but not to the average lengthwise velocity of the fluid.

Practical application

In a hydraulic engineering application, it is typical for the volumetric flow within a pipe and the head loss per unit length to be the critical important factors. The practical consequence is that, for a fixed volumetric flow rate, head loss decreases with the inverse fifth power of the pipe diameter,. Doubling the diameter of a pipe of a given schedule roughly doubles the amount of material required per unit length and thus its installed cost. Meanwhile, the head loss is decreased by a factor of 32. Thus the energy consumed in moving a given volumetric flow of the fluid is cut down dramatically for a modest increase in capital cost.