Dew point
The dew point is the temperature to which air must be cooled to become saturated with water vapor. When cooled further, the airborne water vapor will condense to form liquid water. When air cools to its dew point through contact with a surface that is colder than the air, water will condense on the surface.
When the temperature is below the freezing point of water, the dew point is called the frost point, as frost is formed via deposition rather than condensation to form dew. The measurement of the dew point is related to humidity. A higher dew point means there is more moisture in the air.
In liquids, the cloud point is the equivalent term.
Humidity
If all the other factors influencing humidity remain constant, at ground level the relative humidity rises as the temperature falls; this is because less vapor is needed to saturate the air. In normal conditions, the dew point temperature will not be greater than the air temperature, since relative humidity cannot exceed 100%.In technical terms, the dew point is the temperature at which the water vapor in a sample of air at constant barometric pressure condenses into liquid water at the same rate at which it evaporates. At temperatures below the dew point, the rate of condensation will be greater than that of evaporation, forming more liquid water. The condensed water is called dew when it forms on a solid surface, or frost if it freezes. In the air, the condensed water is called either fog or a cloud, depending on its altitude when it forms. If the temperature is below the dew point, and no dew or fog forms, the vapor is called supersaturated. This can happen if there are not enough particles in the air to act as condensation nuclei.
A high relative humidity implies that the dew point is close to the current air temperature. A relative humidity of 100% indicates the dew point is equal to the current temperature and that the air is maximally saturated with water. When the moisture content remains constant and temperature increases, relative humidity decreases, but the dew point remains constant.
General aviation pilots use dew point data to calculate the likelihood of carburetor icing and fog, and to estimate the height of a cumuliform cloud base.
across a range of temperatures can contain. For a lower ambient pressure, a curve has to be drawn above the current curve. A higher ambient pressure yields a curve under the current curve.
Increasing the barometric pressure increases the dew point. This means that, if the pressure increases, the mass of water vapor in the air must be reduced in order to maintain the same dew point. For example, consider New York City and Denver. Because Denver is at a higher elevation than New York, it will tend to have a lower barometric pressure. This means that if the dew point and temperature in both cities are the same, the amount of water vapor in the air will be greater in Denver.
Relationship to human comfort
When the air temperature is high, the human body uses the evaporation of sweat to cool down, with the cooling effect directly related to how fast the perspiration evaporates. The rate at which perspiration can evaporate depends on how much moisture is in the air and how much moisture the air can hold. If the air is already saturated with moisture, perspiration will not evaporate. The body's thermoregulation will produce perspiration in an effort to keep the body at its normal temperature even when the rate at which it is producing sweat exceeds the evaporation rate, so one can become coated with sweat on humid days even without generating additional body heat.As the air surrounding one's body is warmed by body heat, it will rise and be replaced with other air. If air is moved away from one's body with a natural breeze or a fan, sweat will evaporate faster, making perspiration more effective at cooling the body. The more unevaporated perspiration, the greater the discomfort.
A wet bulb thermometer also uses evaporative cooling, so it provides a good measure for use in evaluating comfort level.
Discomfort also exists when the dew point is very low. The drier air can cause skin to crack and become irritated more easily. It will also dry out the airways. The US Occupational Safety and Health Administration recommends indoor air be maintained at with a 20–60% relative humidity, equivalent to a dew point of.
Lower dew points, less than, correlate with lower ambient temperatures and causes the body to require less cooling. A lower dew point can go along with a high temperature only at extremely low relative humidity, allowing for relatively effective cooling.
People inhabiting tropical and subtropical climates acclimatize somewhat to higher dew points. Thus, a resident of Singapore or Miami, for example, might have a higher threshold for discomfort than a resident of a temperate climate like London or Chicago. People accustomed to temperate climates often begin to feel uncomfortable when the dew point gets above, while others might find dew points up to comfortable. Most inhabitants of temperate areas will consider dew points above oppressive and tropical-like, while inhabitants of hot and humid areas may not find this uncomfortable. Thermal comfort depends not just on physical environmental factors, but also on psychological factors.
Measurement
Devices called hygrometers are used to measure dew point over a wide range of temperatures. These devices consist of a polished metal mirror which is cooled as air is passed over it. The temperature at which dew forms is, by definition, the dew point. Manual devices of this sort can be used to calibrate other types of humidity sensors, and automatic sensors may be used in a control loop with a humidifier or dehumidifier to control the dew point of the air in a building or in a smaller space for a manufacturing process.Calculating the dew point
A well-known approximation used to calculate the dew point, Tdp, given just the actual air temperature, T and relative humidity, RH, is the Magnus formula:The more complete formulation and origin of this approximation involves the interrelated saturated water vapor pressure at T, Ps, and the actual vapor pressure, Pa, which can be either found with RH or approximated with the barometric pressure, BPmbar, and "wet-bulb" temperature, Tw is :
For greater accuracy, Ps can be enhanced, using part of the Bögel modification, also known as the Arden Buck equation, which adds a fourth constant d:
where
- a = 6.1121 mbar, b = 18.678, c = 257.14 °C, d = 234.5 °C.
- a = 6.112 mbar, b = 17.67, c = 243.5 °C.
Also noteworthy is the Sonntag1990,
- a = 6.112 mbar, b = 17.62, c = 243.12 °C; for .
- a = 6.105 mbar, b = 17.27, c = 237.7 °C; for .
- a = 6.1121 mbar, b = 17.368, c = 238.88 °C; for .
- a = 6.1121 mbar, b = 17.966, c = 247.15 °C; for .
Simple approximation
This can be expressed as a simple rule of thumb:
For every 1 °C difference in the dew point and dry bulb temperatures, the relative humidity decreases by 5%, starting with RH = 100% when the dew point equals the dry bulb temperature.
The derivation of this approach, a discussion of its accuracy, comparisons to other approximations, and more information on the history and applications of the dew point are given in the Bulletin of the American Meteorological Society.
For temperatures in degrees Fahrenheit, these approximations work out to
For example, a relative humidity of 100% means dew point is the same as air temp. For 90% RH, dew point is 3 °F lower than air temperature. For every 10 percent lower, dew point drops 3 °F.