Fall arrest
Fall arrest is the form of fall protection which involves the safe stopping of a person already falling. It is one of several forms of fall protection, forms which also include fall guarding and fall restraint.
The U.S. Department of Labor's Occupational Safety and Health Administration specifies under Title 29 of the Code of Federal Regulations that individuals working at height must be protected from fall injury, and fall arrest is one of several forms of fall protection as defined within that Code.
Personal fall arrest systems
Fall arrest is of two major types: general fall arrest, such as nets; and personal fall arrest, such as lifelines. The most common manifestation of fall arrest in the workplace is the Personal Fall Arrest System, or PFAS.Such a system should include 5 elements referred to as ABCDs of Fall Arrest:
- A – Anchorage – a fixed structure or structural adaptation, often including an anchorage connector, to which the other components of the PFAS are rigged.
- B – Body Wear – a full body harness worn by the worker.
- C – Connector – a subsystem component connecting the harness to the anchorage – such as a lanyard.
- D – Deceleration Device – an essential subsystem component designed to dissipate the forces associated with a fall arrest event. It is good practice and recommended that these are also included in Restraint systems, in case of foreseeable mis-use.
- E – Emergency Plan & Equipment – a clear and simple approach to rescue of a suspended worker following a fall arrest event. All workers should be familiar with the site specific plan and competent to implement it. If a suspended worker is not recovered in good time, they may suffer the potentially serious effects of "suspension trauma".
Fall protection training
Workers are required to have training in the use of fall protection equipment. This is legislated by Occupational Health and Safety Groups such as OSHA in the USA, and in Canada, the Provincial legislative bodies. Training is required to include instruction on theoretical aspects of using the equipment, and also practical aspects. Typically a fall protection, sometimes called fall arrest class is 8 hours long for general workers, but may include a second 8 hours of training for workers who climb communication towers, or oil derricks.Energy absorption
To arrest a fall in a controlled manner, it is essential that there is sufficient energy absorption capacity in the system. Without this designed energy absorption, the fall can only be arrested by applying large forces to the worker and to the anchorage, which can result in either or both being severely affected.An analogy for this energy absorption is to consider the difference in dropping an egg onto a stone floor or dropping it into soft mud. Even for the same fall distance and weight of egg, there will be more damage with the stone floor as the arrest distance is smaller and so forces must be higher to dissipate the energy. For the soft mud, the arrest distance is longer and so arrest forces are lower but the egg is still stopped and is hopefully undamaged.
Because fall arrest designs require high-rate-energy capacity design methods, fundamental fall arrest design is tedious and esoteric. Thus, most fall arrest parts and systems are designed to the force standards contained in Federal OSHA 29CFR1910.66 appendix c, a force-type design standard which accounts for required energy considerations. The standard mitigates PPE interchangeability problems, allows wide use by designers not versed in high rate energy methods, and it limits the force into the worker to a survivable level.
Actual loads on the user and anchor-anchorage vary widely with user weight, height of fall, geometry, and type of line/rope. Excessive energy into the support and user is avoided by the use of energy absorbing PPE designed for the 1800 lbs maximum of the referenced Federal OSHA standard.
The most common fall arrest system is the vertical lifeline: a stranded rope that is connected to an anchor above, and to which the user's PPE is attached either directly or through a "shock absorbing" lanyard. Once all of the components of the particular lifeline system meet the requirements of the standard, the anchor connection is then referred to as an anchorage, and the system as well as the rope is then called a "lifeline".
Anchors used for lifeline anchorages are designed for force per connecting user, and the standard permits an anchor to deform in order to absorb energy.
The rope can be lifeline rope, which stretches to lengthen the fall distance as it absorbes energy; or static rope, which does not stretch and thus limits the fall distance, but requires the fall energy be absorbed in other devices. It is essential that the PPE be rated for Fall Arrest and PPE used with static line include an energy absorber. While the energy absorbing lanyards hold in excess of when fully absorbed, most limit the load during the fall to under.
Another common system is an HLL. These are linear anchoring devices, which allow workers to move along the whole length of the anchor, usually without needing to disconnect and fixing points of the anchorage.
It is normally essential to include energy absorbers within HLL in addition to those within the workers' PPE. Without such absorbers, the horizontal life line cannot deform significantly when arresting the fall. Because of the geometry of pulling across the horizontal line, this in turn results in large resolved forces being generated within the anchor system, sufficient to cause failure of the anchorage. This can occur even with energy absorbers being included in the PPE of the worker.
The load and horizontal line geometry in horizontal lifelines usually creates falls in excess of the limit of the standard, limiting HLL design to standard-defined "qualified persons".
Fall clearance
In arresting a fall in a controlled manner, the distance required to arrest the fall must be considered. Federal OSHA limits the fall distance to unless the specific system is designed by a "qualified person" meeting the requirements of OSHA 29CFR1910.66 appendix c. The user also may not fall so as to strike protrusions or adjoining walls during the fall.The safe fall distance is a function of the fall factor and the deployment of the "energy absorbers". As a rule of thumb for a factor 2 fall, a fall distance of approx will be required. This is equivalent to 2 stories of a building. If the fall clearance is less than this the worker may strike the ground before his fall is arrested.