Floodgates, also called stop gates, are adjustable gates used to control water flow in flood barriers, reservoir, river, stream, or levee systems. They may be designed to set spillway crest heights in dams, to adjust flow rates in sluices and canals, or they may be designed to stop water flow entirely as part of a levee or storm surge system. Since most of these devices operate by controlling the water surface elevation being stored or routed, they are also known as crest gates. In the case of flood bypass systems, floodgates sometimes are also used to lower the water levels in a main river or canal channels by allowing more water to flow into a flood bypass or detention basin when the main river or canal is approaching a flood stage.
Types
Valves
Valves used in floodgate applications have a variety of design requirements and are usually located at the base of dams. Often, the most important requirement is energy dissipation. Since water is very heavy, it exits the base of a dam with the enormous force of water pushing from above. Unless this energy is dissipated, the flow can erode nearby rock and soil and damage structures. Other design requirements include taking into account pressure head operation, the flow rate, whether the valve operates above or below water, and the regulation of precision and cost.
Fixed cone valves are designed to dissipate the energy from a water flow during reservoir discharge. They are a round pipe section with an adjustable sleeve gate and cone at the discharge end. Flow is varied by moving the sleeve away or towards its cone seat. The design allows high pressure water from the base of a dam to be released without causing erosion to the surrounding environment. Fixed cone valves are able to handle heads up to 300 m.
Hollow jet valves are a type of needle valve used for floodgate discharge. A cone and seat are inside a pipe. Water flows through an annular gap between the pipe and cone when it is moved downstream, away from the seat. Ribs support the bulb assembly and supply air for water jet stabilization.
Ring jet valves are similar to fixed cone valves, but have an integral collar that discharges water in a narrow stream. They are suitable for heads up to 50 m.
Jet flow gate, similar to a gate valve but with a conical restriction prior to the gate leaf that focuses the water into a jet. They were developed in the 1940s by the United States Bureau of Reclamation to allow fine control of discharge flow without the cavitation seen in regular gate valves. Jet flow gates are able to handle heads up to 150 m.
Physics
The force on a rectangular flood gate can be calculated by the following equation: where: If the rectangular flood gate is submerged below the surface the same equation can be used but only the height from the water surface to the middle of the gate must be used to calculate the force on the flood gate.