An integral bridge contains no expansion joints to accommodate enlargement due to increased temperature. Horizontal movements due to thermal expansion and braking loads are instead transferred to the fill adjacent to the abutment. The omission of the expansion joint removes a pathway for the penetration of chloride-bearing road salts to the bridge's sub-structure. In the United Kingdom there is a presumption that most new short to medium length bridges will be of the integral type.
An early example of an integral bridge is masonry arch bridge. Some of the earliest examples of integral bridges in reinforced concrete were constructed as part of the United Kingdom's M1 motorway in 1959.

Description

An integral bridge contains no expansion joints, spanning monolithically from abutment to abutment. Movement due to thermal expansion and contraction or braking loads is accommodated by the end walls or abutments. Where intermediate supports are specified these may also serve to resist thermal expansion movements.
The omission of the expansion joint removes a significant maintenance and durability issue, as it serves as a point of ingress for road salts which allows the abutment, piers and deck soffit concrete to come under chloride attack that can cause degradation and eventual span failure. A 1989 British study showed that the majority of expansion joints surveyed in existing bridges had failed and allowed water ingress.
The movement experienced at the abutment in an integral bridge is an order of magnitude greater than those designed with movement joints. The size of movement depends on the stiffness of the bridge structure and the fill adjacent to the abutment. The movement is largest in the upper portion of the abutment, where thermal effects are greatest. Highways England specify that integral bridges should be designed to limit movement to. Due to repeated expansion and contraction cycles the backfill adjacent to the abutment is subject to ratcheting, whereby the material's stiffness is increased. The maximum stiffness level is reached after around 100–200 thermal expansion cycles.

Types

Highways England recognises four types of integral bridge, defined by the construction of their abutments:
Where bridge bearings are used on an integral bridge the structure is sometimes referred to as semi-integral.

Use

It is widely accepted that short to medium length bridges should be designed as integral structures to minimise maintenance requirements. Highways England's Design Manual for Roads and Bridges states that all bridges with deck length less than and skew of less than 30 degrees should be designed as integral structures unless there is a compelling reason to do otherwise.