Kingston Power Station, London
Kingston Power Station was a coal-fired generating station on the Thames in Kingston upon Thames, Surrey. It ceased generating in 1980 and has been demolished.
History
The first station was built in 1893, with an original capacity of 225 kW. New generating equipment was added as the demand for electricity increased. The generating capacity, maximum load, and electricity generated and sold was as follows:Year | Generating capacity, MW | Maximum load, MW | Electricity generated, GWh | Electricity sold, GWh |
1912/3 | 0.860 | 0.670 | 1.332 | 1.152 |
1918/9 | 2.00 | 0.95 | 2.175 | 1.608 |
1919/20 | 2.00 | 1.25 | 2.208 | 1.848 |
1923/4 | 4.50 | 2.00 | 4.081 | 2.394 |
1936/7 | 11.75 | 7.293 | None | 19.140 |
The A station eventually closed in 1959. A new 'B' station was planned before World War II, opening in 1948. The Thames was used both for coal supply and ash removal, and as a source of cooling water. The new station was the first to be opened following nationalisation of the power industry, with the official opening by King George VI, the first station to receive such an honour since Barking in 1924.
Technical Specification
In 1923 the plant comprised two 1,250 kW turbo-alternators, these were supplied from the boiler plant which produced a total of 66,000 lb/hr of steam. Electricity was available at 3-phase AC, 50 Hz at 440, 415 & 240V and single phase AC, 77 Hz at 210 & 105V. In 1923 the station generated 3.448 GWh of electricity, some of this was used in the plant, the total amount sold was 1.888 GWh. The revenue from sales of current was £39,623, this gave a surplus of revenue over expenses of £21,124.By 1966 Kingston B power station had 4 × 30 MW British Thomson-Houston turbo-alternators, giving a generating capacity of 123 MW. The chain grate stoker Stirling boilers had a steam capacity of 1,710,000 lb/hr. The steam conditions at the turbine stop valve were 600 psi and 454°C. The overall thermal efficiency of the station in 1966 was 21.12 per cent.
Electricity output from Kingston power station was as follows.
Kingston annual electricity output GWh.