Leica M5
The Leica M5 is a 35 mm camera by Leica Camera AG, introduced in 1971. It was the first Leica rangefinder camera to feature through-the-lens metering and the last to be made entirely in Wetzlar by hand using the traditional "adjust and fit" method.
Design
The M5 departed from the traditional silhouette of the Leica rangefinders, that had few changes since the M3. The height and width of the body were larger, and the body heavier. The folding film rewinding crank hides in the bottom plate. The self-timer arm and the field-of-view preselector are of the same design as the Leica M4. The M5 was the last M to feature a mechanical self-timer. The M5 incorporates an improved rapid film loading spool design over the M4. The M5 has a rapid transport lever which winds the shutter and advances the film and the frame counter in one single motion, or in a series of shorter motions. A marker for the film plane is engraved on the top of the camera housing. The M5's redesigned horizontal travelling cloth focal plane shutter is reported to be the quietest of the M series. The shutter curtains travel at a relatively low speed which has as a consequence the 1/50 second flash sync speed.Viewfinder
The M5's optical rangefinder / viewfinder mechanism is based on the M4. The M5 has 0.72 viewfinder magnification, with a 68.5 mm RF Base Length and 49.32 mm Effective Base Length,. No other magnifications are offered with this model. The M5 is sometimes said to have the best viewfinder of the M series. It is fully adjustable using setting screws, and is not glued as in the later M-series. The M5 viewfinder does not have the blue tint of the earlier M2/M3. Its lens surfaces are multicoated, reducing flare. As with other.72 magnification finders, the M5 can suffer from RF 'white-out', but this is less pronounced than on all following M-series until the coming of the Leica MP.Exposure meter
The exposure meter uses a circular CdS cell 8.5 mm in diameter, and having a sensitivity of -0 - 20 Ev at 100 ASA. Information from the exposure meter is displayed using a dual match needle system at the bottom of the viewfinder. An additional illuminator window at the top of the viewfinder illuminates the readout bar. The M5 exposure meter can be set from ISO 6/9° to ISO 3200/36°. The ASA/DIN film speed knob is designed to prevent inadvertent change. The meter's circuit is powered up by winding the camera, and shuts down when the shutter is released. The M5 exposure meter required the PX625 1.35 V mercuric oxide coin type cell which was banned because of its mercury content. The M5 continues to run on a number of alternatives including the Weincell MRB625. The battery compartment is located between the strap lugs. It is accessed by using a coin slot type threaded cap and is superior in design to that of the bayonet caps that surfaced as of the M6.Shutter dial
The M5 has the largest M shutter speed dial. It is coaxial with the shutter button and overhangs the top plate, making for very comfortable and quick manipulation, adjustable without taking the camera from your eye. This ergonomic feature is often cited as one of the M5's paradigmatic advantages, and a non-coaxial variant was later reintroduced as of the M6 TTL. The M5 is the only full-size M with shutter speeds visible in the finder. It allows reliable, linear intermediate speeds between full click stops from the 1/1000 through to the 1/2 second setting. The speed dial is additionally engraved with "B" speeds from 1 to 30 seconds. These settings are coupled with the light meter, but the exposure time must be manually implemented using a cable release. The camera's internal exposure timing mechanism disengages below the 1/2 second setting. The shutter release button is threaded for a standard cable release. The M5 is capable of making double exposures.Vertical strap lugs
Leica originally placed the strap lugs in order to hang the camera vertically. This was met by resistance by users prompting the addition of a third lug. The installation of the third lug is available for earlier cameras. As some users have pointed out, the vertical positioning of the camera is effective when the camera strap is across the chest, allowing the M5 to be brought to eye level quickly while remaining otherwise partially hidden and protected under the arm. This necessitates the use of the proprietary Leica flat shoulder strap.M5 Jubilee Special Edition
In 1975 a 50-year jubilee edition of 1750 units was produced.Reception
Leica M5 sales were very disappointing, and production was halted in 1975 after 33,900 units. Cost on issue for the M5 body in today's currency is c. US$4200.- Rangefinder camera sales were seriously undermined during this period by the predominance of mass-produced SLRs, primarily from Japan. In addition, Leica unofficially continued selling the M4, and the Leica CL was fully represented in the market by 1973.
- Often cited as also contributing to the poor sales are the larger size and weight, the departure from the classical M design, the impossibility of attaching a motor winder, as well as the incompatibility with certain deep-seated wide angle lenses and collapsible lenses.
- The larger body dimensions also prevent the use of many M series accessories, such as external hand grips, quick release plates for tripod heads, or the Leica Lens Carrier M.
Known issues
- Any precision mechanical camera like the M5 needs expert calibration and maintenance. The servicing of an M5 to factory specifications will cost typically US$200–400. This is also the case for cameras that have seen little or no use. It is not advisable to use an M5 before a qualified CLA, as the lubricants may have hardened and damage can result.
- Serial numbers above 134xxxx are usually considered more reliable as earlier problems in the production line were resolved by then.
- The CdS cell is only accurate when the camera is held horizontally; although the difference is reported to be inconsequential.
- The meter generally has been observed to have up to a 1/2 stop deviation varying over the spectrum of its performance specification.
- The exposure meter's mechanical arm is retracted by depressing the shutter release button. As a result, the exposure meter will not produce a usable reading if the shutter release button is under any pressure.
- Issues surrounding the fragility of the CdS cell affect many extant M5s; it is still available as a replacement part.
- In Leica M series cameras that have seen little use, the spring securing the lensmount bayonet lock may be weak or have its motion impaired. This can create the risk of a lens disengaging and dropping from the camera body while focusing.
- The M5 is covered in vulcanite, which can become brittle with age, and is subject to peeling and cracking. The M5 can be recovered with a variety of comparable materials such as Griptac.
- The 0.72 viewfinder magnification has the consequence that the 35 mm framelines are not easily visible for users wearing eyeglasses; an optional eyepiece diopter may be screwed into the viewfinder to remedy this. The astigmatic custom eyepiece diopter is no longer offered by Leica.
- The cloth shutter susceptible to getting pinholes burned in it by an uncapped lens in bright sunlight.
- The camera should always be stored uncocked. The tensions on the horizontal cloth shutter may otherwise damage it.