Open-pool Australian lightwater reactor
The Open-pool Australian lightwater reactor is a 20 megawatt pool-type nuclear research reactor. Officially opened in April 2007, it replaced the High Flux Australian Reactor as Australia's only nuclear reactor, and is located at the Australian Nuclear Science and Technology Organisation Research Establishment in Lucas Heights, New South Wales, a suburb of Sydney. Both OPAL and its predecessor have been commonly known as simply the Lucas Heights reactor, after their location.
Functions
The main reactor uses are:- Irradiation of target materials to produce radioisotopes for medical and industrial applications
- Research in the fields of materials science and structural biology using neutron beams and its sophisticated suite of experimental equipment
- Analysis of minerals and samples using the neutron activation technique and the delay neutron activation technique
- Irradiation of silicon ingots in order to dope them with phosphorus and produce the basic material used in the manufacturing of semiconductor devices
During year 2014 OPAL ran a total of 290 days at power, and over 300 days in 2015.
History
The Argentine company INVAP was fully responsible through a turnkey contract, signed in June 2000, for the delivery of the reactor, performing the design, construction and commissioning. Local civil construction was performed by INVAP's partner, John Holland-Evans Deakin Industries. The facility features a large liquid-deuterium cold neutron source, modern supermirror guides, and a guide hall. The cold source was designed by the Petersburg Nuclear Physics Institute, the cryogenic system designed and supplied by Air Liquide and the initial set of four supermirror guides supplied by Mirrotron.On 17 December 2001, 46 Greenpeace activists occupied the Lucas Heights facility to protest the construction of OPAL. Protestors gained access to the grounds, the HIFAR reactor, the high-level radioactive waste store and the radio tower. Their protest highlighted the security and environmental risks of the production of nuclear materials and the shipment of radioactive waste from the facility.
OPAL was opened on 20 April 2007 by then Australian Prime Minister John Howard and is the replacement for the HIFAR reactor. ANSTO received an operating licence from the Australian Radiation Protection and Nuclear Safety Agency in July 2006, allowing commencement of hot commissioning, where fuel is first loaded into the reactor core. OPAL went critical for the first time on the evening of 12 August 2006 and reached full power for the first time on the morning of 3 November 2006.
Facility details
The reactor core consists of 16 low-enriched plate-type fuel assemblies and is located under of water in an open pool. Light water is used as the coolant and moderator while heavy water is used as the neutron reflector. The purpose of the neutron reflector is to improve neutron economy in the reactor, and hence to increase the maximum neutron flux.OPAL is the centrepiece of the facilities at ANSTO, providing radiopharmaceutical and radioisotope production, irradiation services, neutron activation analysis and neutron beam research. OPAL is able to produce four times as many radioisotopes for nuclear medicine treatments as the old HIFAR reactor, and a wider array of radioisotopes for the treatment of disease. The modern design includes a cold neutron source.
The OPAL reactor already has received seven awards in Australia.
Neutron scattering at OPAL
The Bragg Institute at ANSTO hosts OPAL's neutron scattering facility. It is now running as a user facility serving the scientific community in Australia and around the world. New funding was received in 2009 in order to install further competitive instruments and beamlines. The actual facility comprises the following instruments:ECHIDNA
ECHIDNA is the name of the high-resolution neutron powder diffractometer. The instrument serves to determine the crystalline structures of materials using neutron radiation analogous to X-ray techniques. It is named after the Australian monotreme echidna, as the spiny peaks of the instrument looks like an echidna.It operates with thermal neutrons. One of the main features is the array of 128 collimators and position sensitive detectors for rapid data acquisition. ECHIDNA allows for structure determinations, texture measurements and reciprocal space mapping of single crystals in most different sample environments serving the physics, chemistry, materials, minerals and earth-science communities. ECHIDNA is part of the Bragg Institute's park of neutron scattering instruments.
Components
- Neutron guide
- : The instrument is located on the TG1 thermal neutron guide of the OPAL reactor. The distance from the reactor is. The position is the second on the guide after the WOMBAT instrument. The size of the guide is high by wide, and it is plated with supermirror coatings.
- Primary collimator
- : There are Söller collimators prior to the monochromator in order to reduce the divergence of the beam and to increase the angular resolution of the instrument. Since this is an intensity compromise, two items of 5' and 10', respectively, can be interchanged or fully removed by an automated mechanism. The collimators cover the full size of the beam delivered by the neutron guide.
- Monochromator
- : The monochromator is made by slabs of Miller index|
oriented Germanium crystals which are inclined towards each other in order to focus down the Bragg reflected beam. The device has been acquired from the Brookhaven National Laboratory in the US after the shutdown of their neutron facility. - Secondary collimator
- : Optionally a secondary collimator with 10' angular acceptance and can be placed in the monochromatic beam between the monochromator and the sample, which again influences the resolution function of the instrument.
- Slit system
- : Two automated sets of horizontal and vertical pairs of absorbing plates allow to cut down the size of the monochromatic beam prior to the secondary collimator and sample size. They remove unwanted neutrons and reduce the background near the detector. In addition, they allow selection of the sample position to be studied.
- Beam monitor
- : A 235U fission monitor measures the amount of neutrons incident to the sample. The efficiency is 10−4 and most neutrons traverse the device undisturbed. The monitor counts are important to correct for beam flux variations due to changes in the reactor or at the upstream instrument.
- Sample stage
- :The sample is supported by a heavy load goniometer consisting of a 360° vertical omega rotation axis, x-y translation tables and a chi-phi cross tilt stage of ±20° range. It can hold a few hundred kilograms in order to support heavier sample environments, such as cryostats, furnaces, magnets, load frames, reaction chambers and others. A typical powder sample is filled into vanadium cans which give little unstructured background. The mentioned sample environment allows measurement of changes in the sample as a function of external parameters, like temperature, pressure, magnetic field, etc. The goniometer stage is redundant for most powder diffraction measurements, but will be important for single crystal and texture measurements, where the orientation of the sample plays a role.
- Detector collimators
- :A set of 128 detectors each equipped which a 5' collimator in front are arranged in a 160° sector focusing to the sample. The collimators select the scattered radiation into the well defined ranges of 128 angular positions. The whole collimator and detector setup is mounted on a common table which is scanned in finer steps around the sample, to be combined further into a continuous diffraction pattern.
- Detector tubes
- :The 128 linear position-sensitive 3He gas detector tubes cover the full opening height of behind the collimators. They determine the position of the neutron event by charge division over the resistive anode towards each end of the detector. Overall and local count rates lie in the several 10000 Hz range.
PLATYPUS
It operates using cold neutrons with a wavelength band of 0.2–2.0 nm. Although up to three different angles of incidence are required for each reflectivity curve, the time-of-flight nature means that timescales of kinetic processes are accessible. By analysing the reflected signal one builds a picture of the chemical structure of the interface. This instrument can be used for examining biomembranes, lipid bilayers, magnetism, adsorbed surfactant layers, etc.
it is named after Ornithorhynchus anatinus, the semi-aquatic mammal native to Australia.
WOMBAT
WOMBAT is a high-intensity neutron powder diffractometer. The instrument serves to determine the crystalline structures of materials using neutron radiation analogous to X-ray techniques. It is named after the wombat, a marsupial indigenous to Australia.It will operate with thermal neutrons. It has been designed for highest flux and data acquisition speed in order to deliver time resolved diffraction patterns in a fraction of a second. Wombat will concentrate on in-situ studies and time critical investigations, such as structure determinations, texture measurements and reciprocal space mapping of single crystals in most different sample environments serving the physics, chemistry, materials, minerals and earth-science communities.
KOWARI
KOWARI is a neutron residual stress diffractometer. Strain scanning using thermal neutrons is a powder diffraction technique in a polycrystalline block of material probing the change of atomic spacing due to internal or external stress. It is named after the kowari, an Australian marsupial.It provides a diagnostic non-destructive tool to optimise e.g. post weld heat treatment of welded structures. Tensile stresses for example drive crack growth in engineering components and compressive stresses inhibit crack growth. Life extension strategies have high economic impact and strain scanning provides the stresses needed to calculate remaining life as well as the means to monitor the condition of components since it is non-destructive. One of the main features is the sample table that will allow examination of large engineering components while orienting and positioning them very accurately.
Others
- TAIPAN - Thermal 3-Axis Spectrometer
- KOALA - Laue Diffractometer
- QUOKKA - Small-Angle Neutron Scattering
- PELICAN - Cold-Neutron Time-of-Flight Spectrometer
- SIKA - Cold 3-Axis Spectrometer
- KOOKABURRA - Ultra-Small-Angle Neutron Scattering
- DINGO - Neutron Radiography, Tomography and Imaging
Performance
The reactor has shown to be a reliable supplier of radiopharmaceuticals, while also serving as a neutron source to conduct material research activities using the several instruments.
Since commissioned the reactor has been running with a very high availability, during the term 2012-13 it operated 265 days at full power, during 2013-14 for 294 days at full power, and during 2014-15 it operated 307 days at full power.
As at September 2016 it has accumulated a total of 2200 equivalent Full Power Days. Each 30 days operating cycle more than 150 batches of Silicon are irradiated, Mo99 is produced on a regular basis for the nuclear medicine market. OPAL has delivered 4 million doses. Regarding research with neutrons the Australian Centre for Neutron Scattering features more than 120 scientists and 13 neutron beam operational instruments, and has produced more than 600 scientific research papers using the neutrons coming from OPAL core.