Rotating unbalance is the uneven distribution of mass around an axis of rotation. A rotating mass, or rotor, is said to be out of balance when its center of mass is out of alignment with the center of rotation. Unbalance causes a moment which gives the rotor a wobbling movement characteristic of vibration of rotating structures.
Causes of unbalance
; Distortion from stress: Routinemanufacturing processes can cause stress on metal components. Without stress relief, the rotor will distort itself to adjust. ; Thermal distortion: Thermal distortion often occurs with parts exposed to increased temperatures. Metals are able to expand when in contact with heat, so exposure to warmer temperatures can cause either the entire piece of machinery to expand, or just certain parts, causing distortion. ; Buildups and deposits: Rotating parts involved in material handlingalmost always accumulate buildup. Moreover, when exposed to oil, these parts can be very easily distorted. Without adhering to a maintenance routine or implementing an inspection process, oil can seep into the parts, causing unbalance.
In terms of the mass eccentricity : µm, mm, cm,...; µin, mil, in,...
In terms of mass at a given radius: µg, mg, g, kg,...; moz, oz,...
In terms of mass × radius moment : mg-mm, g-mm, mg-cm, g-cm, kg-mm,...; oz-in, g-in,...
Types of balance
Static balance
A static balance occurs when the inertial axis of a rotating mass is displaced from and parallel to the axis of rotation. Static unbalances can occur more frequently in disk-shaped rotors because the thin geometric profile of the disk allows for an uneven distribution of mass with an inertial axis that is nearly parallel to the axis of rotation. Only one plane receives balance correction. where U = balance, m = mass, r = distance between unbalance and the centre of the object
Couple balance
A couple balance occurs when a rotating mass has two equal unbalance forces that are situated 180° opposite each other. A system that is statically balanced may still have a couple unbalance. Couple unbalance occurs frequently in elongated cylindrical rotors. where d = distance between the two unbalance forces along the rotation axis.
Dynamic balance
In rotation an unbalance when the mass/inertia axis does not intersect with shaft axis then it is called dynamic balance. Combination of static and couple balance is dynamic unbalance. It occurs in virtually all rotors and is the most common kind of unbalance. It can be fixed by correcting the weight on at least two planes.
The measurement of existing vibration and calculation of the change of mass required is typically carried out using some form of balancing machine.
Grades
21940 classifies vibration in terms of G codes. Unfortunately, it is the theoretical value assuming the rotor was spinning in free space so it does not relate to actual operating conditions. Rotors of the same type having permissible residual specific unbalance value eper, varies inversely with the speed of the rotor. where ω = angular velocity eper = permissible residual specific unbalance This constant is quality grade G. Balance Grades are used to specify the allowable residual imbalance for rotating machinery. The ISO 1940 standard defines balance grades for different classes of machinery. A rotor balanced to G2.5 will vibrate at 2.5 mm/s at operating speed if rotating in a suspended state with no external influences.
Where Uper = balance tolerance residual imbalance
Important formulas
Where F = force due to unbalance, U = unbalance. ω = angular frequency. e = specific unbalance. m = mass. r = distance between unbalance and the axis of rotation of the object.