Run-length limited
Run-length limited or RLL coding is a line coding technique that is used to send arbitrary data over a communications channel with bandwidth limits. RLL codes are defined by four main parameters: m, n, d, k. The first two, m/n, refer to the rate of the code, while the remaining two specify the minimal d and maximal k number of zeroes between consecutive ones. This is used in both telecommunication and storage systems that move a medium past a fixed recording head.
Specifically, RLL bounds the length of stretches of repeated bits during which the signal does not change. If the runs are too long, clock recovery is difficult; if they are too short, the high frequencies might be attenuated by the communications channel. By modulating the data, RLL reduces the timing uncertainty in :wikt:decode|decoding the stored data, which would lead to the possible erroneous insertion or removal of bits when reading the data back. This mechanism ensures that the boundaries between bits can always be accurately found, while efficiently using the media to reliably store the maximal amount of data in a given space.
Early disk drives used very simple encoding schemes, such as RLL FM code, followed by RLL MFM code which were widely used in hard disk drives until the mid-1980s and are still used in digital optical discs such as CD, DVD, MD, Hi-MD and Blu-ray. Higher density RLL and RLL codes became the de facto industry standard for hard disks by the early 1990s.
Need for RLL coding
On a hard disk drive, information is represented by changes in the direction of the magnetic field on the disk, and on magnetic media, the playback output is proportional to the density of flux transition. In a computer, information is represented by the voltage on a wire. No voltage on the wire in relation to a defined ground level would be a binary zero, and a positive voltage on the wire in relation to ground represents a binary one. Magnetic media, on the other hand, always carries a magnetic flux - either a "north" pole or a "south" pole. In order to convert the magnetic fields to binary data, some encoding method must be used to translate between the two.One of the simplest practical codes, Modified Non-Return-to-Zero-Inverted, simply encodes a 1 as a magnetic polarity transition, also known as a "flux reversal", and a zero as no transition. With the disk spinning at a constant rate, each bit is given an equal time period, a "data window," for the magnetic signal that represents that bit, and the flux reversal, if any, occurs at the start of this window.
This method is not quite that simple, as the playback output is proportional to the density of ones, a long run of zeros means no playback output at all.
In a simple example, consider the binary pattern 101 with a data window of 1 ns. This will be stored on the disk as a change, followed by no change, and then another change. If the preceding magnetic polarity was already positive, the resulting pattern might look like this: −−+. A value of 255, or all binary ones, would be written as −+−+−+−+ or +−+−+−+−. A zero byte would be written as ++++++++ or −−−−−−−−. A 512 byte sector of zeros would be written as 4,096 sequential bits with the same polarity.
Since a disk drive is a physical piece of hardware, the rotational speed of the drive can change slightly, due to a change in the motor speed or thermal expansion of the disk platter. The physical media on a floppy disk can also become deformed, causing larger timing errors, and the timing circuit on the controller itself may have small variations in speed. The problem is that, with a long string of zeros, there's no way for the disk drive's controller to know the exact position of the read head, and thus no way to know exactly how many zeros there are. A speed variation of even 0.1% - which is more precise than any practical floppy drive - could result in four bits being added to or removed from the 4,096 bit data stream. Without some form of synchronization and error correction, the data would become completely unusable.
The other problem is due to the limits of magnetic media itself: it is only possible to write so many polarity changes in a certain amount of space, so there's an upper limit to how many 1's can also be written sequentially, this depends on the linear velocity and the head gap.
To prevent this problem, data is coded in such a way that long repetitions of a single binary value do not occur. By limiting the number of zeros written consecutively, this makes it possible for the drive controller to stay in sync. By limiting the number of 1's written in a row, the overall frequency of polarity changes is reduced, allowing the drive to store more data in the same amount of space, resulting in either a smaller package for the same amount of data or more storage in the same size package.
History
All codes used to record on magnetic disks have limited the length of transition-free runs and can therefore be characterized as RLL codes. The earliest and simplest variants were given specific names, such as Modified Frequency Modulation, and the name "RLL" is commonly used only for the more complex variants not given such specific names, but the term technically applies to them all.The first "RLL" code used in hard drives was RLL, developed by IBM engineers and first used commercially in 1979 on the IBM 3370 DASD, for use with the 4300 series mainframe. During the late 1980s, PC hard disks began using RLL proper. RLL codes have found almost universal application in optical disc recording practice since 1980. In consumer electronics, RLLs like the EFM code are employed in the Compact Disc and MiniDisc, and the EFMPlus code used in the DVD. Parameters d, k are the minimum and maximum allowed run-lengths. For more coverage on the storage technologies, the references cited in this article are useful.
Technical overview
Generally run-length is the number of bits for which signal remains unchanged. A run-length of 3 for bit 1, represents a sequence of '111'. For instance, the pattern of magnetic polarizations on the disk might be '+−−−−++−−−++++++', with runs of length 1, 4, 2, 3, and 6. However, run length limited coding terminology assumes NRZI encoding, so 1 bits indicate changes and 0 bits indicate the absence of change, the above sequence would be expressed as '11000101001000001', and only runs of zero bits are counted.Somewhat confusingly, the run length is the number of zeros between adjacent ones, which is one less than the number of bit times the signal actually remains unchanged. Run length limited sequences are characterized by two parameters, d and k, which stipulate the minimum and maximum zero-bit run length that can occur in the sequence. So RLL codes are generally specified as RLL. e.g.: RLL.
Coding
In the encoded format a "1" bit indicates a flux transition, while a "0" indicates that the magnetic field on the disk does not change for that time interval.FM: (0,1) RLL
Generally, the term "RLL code" is used to refer to more elaborate encodings, but the original frequency modulation code, also called differential Manchester encoding, can be seen as a simple rate-1/2 RLL code.The added 1 bits are referred to as clock bits.
Example:
Data: 0 0 1 0 1 1 0 1 0 0 0 1 1 0
Encoded: 1010111011111011101010111110
Clock: 1 1 1 1 1 1 1 1 1 1 1 1 1 1
GCR: (0,2) RLL
By extending the maximum run length to 2 adjacent 0 bits, the data rate can be improved to 4/5. This is the original IBM group coded recording variant.Where possible, the bit pattern abcd is encoded by prefixing it with the complement of a: abcd . In the five cases where this would violate one of the rules, a code beginning with 11 is substituted.Example: Data: 0010 1101 0001 1000 Encoded: 10010011011101111010 Note that to meet the definition of RLL, it is not sufficient only that each 5-bit code contain no more than two consecutive zeros, but it is also necessary that any pair of 5-bit codes as a combined sequentially not contain more than two consecutive zeros. That is, there must not be more than two zeros between the last one bit in the first code and the first one bit in the second code, for any two arbitrarily chosen codes. This is required because for any RLL code, the run length limits—0 and 2 in this case—apply to the overall modulated bitstream, not just to the components of it that represent discrete sequences of plain data bits. The IBM GCR code above meets this condition, since the maximum run length of zeros at the beginning of any 5-bit code is one, and likewise the maximum run length at the end of any code is one, making a total run length of two at the junction between adjacent codes. MFM: (1,3) RLLbegins to get interesting, because its special properties allow its bits to be written to a magnetic medium with twice the density of an arbitrary bit stream. There is a limit to how close in time flux transitions can be for reading equipment to detect them, and that constrains how closely bits can be recorded on the medium: In the worst case, with an arbitrary bit stream, there are two consecutive 1's, which produces two consecutive flux transitions in time, so bits must be spaced far enough apart that there would be sufficient time between those flux transitions for the reader to detect them. But this code imposes a constraint of d=1, i.e. there is a minimum of one 0 between each two 1's. That means in the worst case, flux transitions are two bit times apart, so the bits can be twice as close together as with the arbitrary bit stream without exceeding the reader's capabilities.This doubled recording density compensates for the 1/2 coding rate of this code and makes it equivalent to a rate-1 code. Where "x" is the complement of the previous encoded bit. Except for the clock bits—that "x" bit, and the "0" in the "01" code—this is the same as the FM table, and that is how this code gets its name. The inserted clock bits are 0 except between two 0 data bits. Example: Data: 0 0 1 0 1 1 0 1 0 0 0 1 1 0 Encoded: x010010001010001001010010100 Clock: x 1 0 0 0 0 0 0 0 1 1 0 0 0 (1,7) RLLRLL maps 2 bits of data onto three bits on the disk, and the encoding is done in two or four bit groups. The encoding rules are: becomes, except becomes.When encoding according to the table below, the longest match must be used; those are exceptions which handle situations where applying the earlier rules would lead to a violation of the code constraints.
Example: Data: 0 0 1 0 1 1 0 1 0 0 0 1 1 0 Encoded: 101 001 010 100 100 000 001 (2,7) RLLRLL is rate- code, mapping n bits of data onto 2n bits on the disk, like MFM, but because the minimum run length is 50% longer, the bits can be written faster, achieving 50% higher effective data density. The encoding is done in two, three or four bit groups.Western Digital WD5010A, WD5011A, WD50C12
Seagate ST11R, IBM
Perstor Systems ADRC
The encoded forms begin with at most four, and end with at most three zero bits, giving the maximum run length of seven. Example: Data: 1 1 0 1 1 0 0 1 1 Encoded: 1000 001000 00001000 DC Free (1,7) RLLThere is also an alternate RLL encoding that is sometimes used to avoid a DC bias.
Where "x" is the complement of the previous encoded bit. Example: Data: 0 1 0 0 1 1 0 1 0 1 Encoded: 010 101 000 000 010 HHH(1,13)The HHH code is a rate-2/3 code developed by three IBM researchers for use in the 16 MB/s IrDA VFIR physical layer. Unlike magnetic encoding, this is designed for an infrared transmitter where a 0 bit represents "off" and a 1 bit represents "on". Because 1 bits consume more power to transmit, this is designed to limit the density of 1 bits to less than 50%. In particular, it is a RLL code, where the final 5 indicates the additional constraint that there are at most 5 consecutive "10" bit pairs.
The first eight rows describe a standard -RLL code. The additional six exceptions increase the maximum run of zeros to 13, but limit the maximum average ones density to. The longest run of 1–0 pairs is 000 101 010 101 000. This code limits the ones density to between and, with an average of 25.8%. ExamplesFor example, let us encode the bit sequence 10110010 with different encodings
DensitiesSuppose a magnetic tape can contain up to 3,200 flux reversals per inch. A Modified Frequency Modulation or RLL encoding stores each data bit as two bits on tape, but since there is guaranteed to be one 0 bit between any 1 bits then it is possible to store 6,400 encoded bits per inch on the tape, or 3,200 data bits per inch. A RLL encoding can also store 6,400 encoded bits per inch on the tape, but since it only takes 3 encoded bits to store 2 data bits this is 4,267 data bits per inch. A RLL encoding takes 2 encoded bits to store each data bit, but since there is guaranteed to be two 0 bits between any 1 bits then it is possible to store 9,600 encoded bits per inch on the tape, or 4,800 data bits per inch.The flux reversal densities on hard drives are significantly greater, but the same improvements in storage density are seen by using different encoding systems. |