Speech transmission index
Speech Transmission Index is a measure of speech transmission quality. The absolute measurement of speech intelligibility is a complex science. The STI measures some physical characteristics of a transmission channel, and expresses the ability of the channel to carry across the characteristics of a speech signal. STI is a well-established objective measurement predictor of how the characteristics of the transmission channel affect speech intelligibility.
The influence that a transmission channel has on speech intelligibility is dependent on:
- the speech level
- frequency response of the channel
- non-linear distortions
- background noise level
- quality of the sound reproduction equipment
- echos
- the reverberation time
- psychoacoustic effects
History
Houtgast and Steeneken developed the Speech Transmission Index while working at The Netherlands Organisation of Applied Scientific Research TNO. Their team at TNO kept supporting and developing the STI, improving the model and developing hardware and software for measuring the STI, until 2010. In that year, the TNO research group responsible for the STI spun out of TNO and continued its work as a privately owned company named Embedded Acoustics. Embedded Acoustics now continues to support development of the STI, with Herman Steeneken still acting as a senior consultant.
In the early years the use of the STI was largely limited to a relatively small international community of speech researchers. The introduction of the RASTI made the STI method available to a larger population of engineers and consultants, especially when Bruel & Kjaer introduced their RASTI measuring device. RASTI was designed to be much faster than the original STI, taking less than 30 seconds instead of 15 minutes for a measuring point. However, RASTI was only intended for pure room acoustics, not electro-acoustics. Application of RASTI to transmission chains featuring electro-acoustic components became fairly common, and led to complaints about inaccurate results. The use of RASTI was even specified by some application standards for applications featuring electro-acoustics, simply because it was the only feasible method at the time. The inadequacies of RASTI were sometimes simply accepted for lack of a better alternative. TNO did produce and sell instruments for measuring full STI and various other STI derivatives, but these devices were relatively expensive, large and heavy.
Around the year 2000, the need for an alternative to RASTI that could also be applied safely to Public Address systems had become fully apparent. At TNO, Jan Verhave and Herman Steeneken started work on a new STI method, that would later become known as STIPA. The first device to include STIPA measurements available for sale to the general public was made by Gold-Line. At this time, STIPA measuring instruments are available from various manufacturers.
RASTI was standardized internationally in 1988, in IEC-60268-16. Since then, IEC-60268-16 was revised three times, the latest revisions appearing in 2011. Each revision included updates of the STI methodology that had become accepted in the STI research community over time, such as the inclusion of redundancy between adjacent octave bands, level-dependent auditory masking and various methods for applying the STI to specific populations such as non-natives and the hearing impaired. An IEC maintenance team is currently working on rev. 5.
RASTI was declared obsolete by the IEC in June 2011, with the appearance of rev. 4 of IEC-602682-16. At this time, this simplified STI derivative was still stipulated as a standard method in some industries. STIPA is now seen as the successor to RASTI for almost every application.
Scale
STI is a numeric representation measure of communication channel characteristics whose value varies from 0 = bad to 1 = excellent. On this scale, an STI of at least.5 is desirable for most applications.Barnett proposed to use a reference scale, the Common Intelligibility Scale, based on a mathematical relation with STI.
STI predicts the likelihood of syllables, words and sentences being comprehended. As an example, for native speakers, this likelihood is given by:
STI value | Quality according to IEC 60268-16 | Intelligibility of syllables in % | Intelligibility of words in % | Intelligibility of sentences in % |
0 – 0.3 | bad | 0 – 34 | 0 – 67 | 0 – 89 |
0.3 – 0.45 | poor | 34 – 48 | 67 – 78 | 89 – 92 |
0.45 – 0.6 | fair | 48 – 67 | 78 – 87 | 92 – 95 |
0.6 – 0.75 | good | 67 – 90 | 87 – 94 | 95 – 96 |
0.75 – 1 | excellent | 90 – 96 | 94 – 96 | 96 – 100 |
If non-native speakers, people with speech disorders or hard-of-hearing people are involved, other probabilities hold.
It is interesting but not astonishing that STI prediction is independent of the language spoken – not astonishing, as the ability of the channel to transport patterns of physical speech is measured.
Another method is defined for computing a physical measure that is highly correlated with the intelligibility of speech as evaluated by speech perception tests given a group of talkers and listeners. This measure is called the Speech Intelligibility Index, or SII.
Nominal qualification bands for STI
The IEC 60268-16 ed4 2011 Standard defines a qualification scale in order to provide flexibility for different applications. The values of this alpha-scale run from "U" to "A+".Standards
STI has gained international acceptance as the quantifier of channel influence on speech intelligibility. The International Electrotechnical Commission Objective rating of speech intelligibility by speech transmission index, as prepared by the TC 100 Technical Committee, defines the international standard.Further the following standards have, as part of the requirements to be fulfilled, integrated testing the STI and realisation of a minimal speech transmission index:
- International Organization for Standardization standard for sound system loudspeakers in Fire detection and fire alarm systems
- National Fire Protection Association Alarm Code
- British Standards Institution Fire detection and alarm systems for buildings
- German Institute for Standardization Sound Systems for Emergency Purposes
STIPA
A single STIPA measurement generally takes between 15 and 25 seconds, combining the speed of RASTI with the wide scope of applicability and reliability of full STI.
Since STIPA has become widely available, and given the fact that RASTI has several disadvantages and no benefits over STIPA, RASTI is now considered obsolete.
Although the STIPA test signal does not resemble speech to the human ear, in terms of frequency content as well as intensity fluctuations it is a signal with speech-like characteristics.
Speech can be described as noise that is intensity-modulated by low-frequency signals. The STIPA signal contains such intensity modulations at 14 different modulation frequencies, spread across 7 octave bands. At the receiving end of the communication system, the depth of modulation of the received signal is measured and compared with that of the test signal in each of a number of frequency bands. Reductions in the modulation depth are associated with loss of intelligibility.
Indirect method
An alternative Impulse response method, also known as the "indirect method," assumes that the channel is linear and requires stricter synchronization of the sound source to the measurement instrument. The main benefit of the indirect method over the direct method is that the full MTF matrix is measured, covering all relevant modulation frequencies in all octave bands. In very large spaces, where echoes are likely to occur, the indirect method is usually preferred over direct method. In general, the indirect method is often the best option when studying speech intelligibility based on "pure room acoustics," when no electro-acoustic components are present within the transmission path.However, the requirement that the channel must be linear implies that the indirect method cannot be used reliably in many real-life applications: whenever the transmission chain features components that might exhibit non-linear behaviour, indirect measurements may yield incorrect results. Also, depending on the type of impulse response measurement that is used, the influence of background noise present during measurements may not be dealt with correctly. This means that the indirect method should only be used with great care when measuring Public Address systems and Voice Evacuation systems. IEC-60268-16 rev. 4 does not disallow the indirect method for such applications, but issues the following words of warning: "Critical analysis is therefore required of how the impulse response is obtained and potentially influenced by non-linearities in the transmission system, particularly as in practice, system components can be operated at the limits of their performance range." In practice, verification of the validity of the linearity assumption is often too complex for everyday use, making the STIPA method the preferred method whenever loudspeakers are involved.
Although many measuring tools based on the indirect method offer STIPA as well as "full STI" options, the sparse Modulation Transfer Function matrix inherent to STIPA offers no advantages when using the indirect method. Impulse response based STIPA measurements must not be confused with direct STIPA measurements, as the validity of the result still depends on whether or not the channel is linear.
List of manufacturers of STI measuring instruments
STI measuring instruments are made by various manufacturers. Below is a list of brands under which STI measuring instruments have been sold, in alphabetical order.- Audio Precision . Offers an STI Plug-in option for use with APx500 Series audio analyzers.
- Audiomatica . Offers an STI tool in CLIO 11 system that is compliant with the latest version of the standard. CLIO 12 system is capable of both indirect STI/STIPA and direct STIPA measurements.
- Bedrock Audio . This is the brand under which Embedded Acoustics sells their STIPA hardware, such as the SM50.
- Brüel & Kjær . Offers handheld as well as software based solutions.
- Gold Line . First to offer STIPA measuring solutions, but currently not offering any tools that comply with the latest standards.
- HEAD acoustics . Offers STI options for both the Artemis Suite and ACQUA test systems.
- Ivie . Offers STIPA-capable acoustic measuring tools such as the IE-45.
- Norsonic . Norsonic was early to adopt STIPA and offer STIPA modules on their instruments. Appears not to be sold in the US.
- NTi Audio . Offers STIPA modules with their AL1 and XL2 line of acoustic measuring instruments as well as a Talkbox and other peripherals. Apparent market leader at this moment.
- Quest . Now part of 3M, Quest produces tools such as the Quest Verifier.
- TNO. Not currently marketing any products, but sold the STIDAS series of measuring instruments before.