Super Proton–Antiproton Synchrotron
The Super Proton–Antiproton Synchrotron was a particle accelerator that operated at CERN from 1981 to 1991. To operate as a proton-antiproton collider the Super Proton Synchrotron underwent substantial modifications, altering it from a one beam synchrotron to a two-beam collider. The main experiments at the accelerator were UA1 and UA2, where the W and Z boson were discovered in 1983. Carlo Rubbia and Simon van der Meer received the 1984 Nobel Prize in Physics for their decisive contribution to the SpS-project, which led to the discovery of the W and Z bosons. Other experiments conducted at the SpS were UA4, UA5 and UA8.
Background
Around 1968 Sheldon Glashow, Steven Weinberg, and Abdus Salam came up with the electroweak theory, which unified electromagnetism and weak interactions, and for which they shared the 1979 Nobel Prize in Physics. The theory postulated the existence of W and Z bosons. It was experimentally established in two stages, the first being the discovery of neutral currents in neutrino scattering by the Gargamelle collaboration at CERN, a process that required the existence of a neutral particle to carry the weak force — the Z boson. The results from the Gargamelle collaboration made calculations of the mass of the W and Z bosons possible. It was predicted that the W boson had a mass value in the range of 60 to 80 GeV/c2, and the Z boson in the range from 75 to 92 GeV/c2 – energies too large to be accessible by any accelerator in operation at that time. The second stage of establishing the electroweak theory would be the discovery of the W and Z bosons, requiring the design and construction of a more powerful accelerator.During the late 70s CERN's prime project was the construction of the Large Electron–Positron Collider. Such a machine was ideal to produce and measure the properties of W and Z bosons. However, due to the pressure to find the W and Z bosons, the CERN community felt like it could not wait for the construction of LEP — a new accelerator was needed — the construction of which could not be at the expense of LEP. In 1976 Carlo Rubbia, Peter McIntyre and David Cline proposed to modify a proton accelerator — at that time a proton accelerator was already running at Fermilab and one was under construction at CERN — into a proton–antiproton collider. Such machine required only a single vacuum chamber, unlike a proton-proton collider that requires separate chambers due to magnetic fields oppositely directed. Since the protons and antiprotons are of opposite charge, but of same energy E, they can circulate in the same magnetic field in opposite directions, providing head-on collisions between the protons and the antiprotons at a total center-of-mass energy. The scheme was proposed both at Fermilab in the United States, and at CERN, and was ultimately adopted at CERN for the Super Proton Synchrotron.
W and Z bosons are produced mainly as a result of quark-antiquark annihilation. In the parton model the momentum of a proton is shared between the proton's constituencies: a portion of the proton momentum is carried by the quarks, and the remainder by gluons. It will not be sufficient to accelerate protons to a momentum equal the mass of the boson, as each quark will only carry a portion of the momentum. To produce bosons in the estimated intervals of 60 to 80 GeV and 75 to 92 GeV, one would therefore need a proton-antiproton collider with a center-of-mass energy of approximately six times the boson masses, about 500-600 GeV. The design of the SpS was determined by the need to detect. As the cross-section for Z production at ~600 GeV is ~1,6 nb, and the fraction of decay is ~3%, a luminosity of L=2,5 · 1029 cm−2s−1 would give an event rate of ~1 per day. To achieve such luminosity one would need an antiproton source capable of producing ~3·1010 antiprotons each day, distributed in a few bunches with angular and momentum acceptance of the SPS.
History
The SPS was originally designed as a synchrotron for protons, to accelerate one proton beam to 450 GeV and extract it from the accelerator for fixed-target experiments. However, already before the construction period of the SPS the idea of using it as a proton-antiproton accelerator came up.The first proposal for a proton-antiproton collider seems to have been made by Gersh Budker and Alexander Skrinsky at Orsay in 1966, based on Budker's new idea of electron cooling. In 1972 Simon van der Meer published the theory of stochastic cooling, for which he later received the 1984 Nobel Prize in Physics. The theory was confirmed in the Intersecting Storage Rings at CERN in 1974. While electron cooling might have led to the idea of a proton-antiproton collider, it was eventually stochastic cooling that was used in the preaccelerators to prepare antiprotons for the SpS.
Meanwhile, the discovery of neutral currents in the Gargamelle experiment at CERN triggered Carlo Rubbia and collaborators proposal for a proton-antiproton collider. In 1978 the project was approved by CERN Council, and the first collisions occurred in July 1981. The first run lasted until 1986, and after a substantial upgrade it continued operation from 1987 to 1991. The collider was shut down at the end of 1991, as it was no longer competitive with the 1,5 TeV proton-antiproton collider at Fermilab, which had been in operation since 1987.
Operation
Between 1981 and 1991 SPS would operate part of the year as a synchrotron, accelerating a single beam for fixed-target experiments, and part of the year as a collider — SpS.Typical parameters | SpS |
Injection momentum | 26 |
Top momentum | 315 |
Integrated luminosity in 1990 | 6790 |
Proton bunch intensity | 12·1010 |
Antiproton bunch intensity | 5·1010 |
Number of bunches per beam | 6 |
Number of collision points | 3 |
Modifications of the SPS for collider operation
The requirements of a storage ring as the SpS, in which beams must circulate for many hours, are much more demanding than those of a pulsed synchrotron, as the SPS. After the SpS was decided in 1978, the following modifications were done on the SPS:- To transfer the antiprotons from the PS to the SPS, a new beam line was constructed, along with a new injection system for counter-clockwise injection.
- As SPS was designed for a 14 GeV/c injection and the new injection would be 26 GeV/c, the injection system had to be upgraded
- Improvement of the SPS beam vacuum system. The design vacuum of 2·10−7 Torr was adequate for SPS — as a synchrotron the beam would be accelerated to 450 GeV and extracted during a very short time. The SpS would have a storage time of 15 to 20 hours, and the vacuum had to be improved by almost three orders of magnitude.
- The accelerating radiofrequency system had to undergo modifications for simultaneous accelerations of protons and antiprotons. The proton and antiproton bunches had to be precisely synchronized for collisions to occur at the center of the detectors.
- Beam diagnostics had to be adapted to low beam intensities. New devices were added, such as directional couplers for independent observation of protons and antiprotons.
- Construction of huge experimental areas for experiments. The beam abort system had to be moved to make place for the experiments.
Antiproton production
at CERN
Filling
After the antiprotons had been stacked up in the AA, the PS and SpS would prepare for a fill. First, three proton bunches, each containing ~1011 protons, were accelerated to 26 GeV in the PS, and injected into the SpS. Second, three bunches of antiproton, each containing ~1010 antiprotons were extracted from the AA and injected into the PS. In the PS the antiproton bunches were accelerated to 26 GeV in the opposite direction of that of the protons, and injected into the SpS. The injections was timed as to ensure that bunch crossings in the accelerator would happen in the center of the detectors, UA1 and UA2. The transfer efficiency from the AA to the SpS was about 80%. In the first run, 1981–1986, the SpS accelerated three bunches of proton and three bunches of antiprotons. After the stacking rate of the antiprotons was increased in the upgrade, the number of both protons and antiprotons injected into the collider was increased from three to six.Acceleration
When injected into the SpS, both beams were accelerated to 315 GeV. It would then pass into storage for 15 to 20 hours of physics data-taking whilst the AA resumed accumulation in preparation for the next fill. As three bunches of protons and three bunches of antiprotons circulated in the same vacuum chamber, they would meet in six points. UA1 and UA2 were placed in two of these meeting points. Electrostatic separators were used to achieve separation at the unused crossing points away from the experiments Until 1983 the centre-of-mass energy was limited to 546 GeV due to resistive heating of the magnetic coils. The addition of further cooling allowed the machine energy to be pushed up to 630 GeV in 1984.Obtaining collisions at 900 GeV
When operated as an accelerator for fixed-target experiments, the SPS can accelerate a beam to 450 GeV, before the beam is extracted within seconds. However, when operated as a collider, the beam has to be stored in the beam line for hours and the dipole magnets of the accelerator must keep a constant magnetic field for a longer time. To prevent overheating the magnets, the SpS would only accelerate the beams to a center-of-mass energy of 315 GeV. This limit could however be overcome by ramping the magnets between 100 GeV and the machines maximum capacity of 450 GeV.The SpS would accelerate the beams to 450 GeV, keeping them as this energy for a time limited by the heating of the magnets, then decelerate the beams to 100 GeV. The pulsing was operated in such a way that the average dispersion of power in the magnets did not exceed the level of operation at 315 GeV. The SpS occasionally ran pulsed operation after 1985, obtaining collisions at a center-of-mass energy of 900 GeV.
Findings and Discoveries
The SpS began its operation in July 1981, and by January 1983 the discovery of the W and Z boson by the UA1 and UA2 experiment were announced. Carlo Rubbia, spokesperson for UA1 experiment, and Simon van der Meer received the 1984 Nobel Prize in Physics for, as stated in the press release from the Nobel Committee, for " their decisive contribution to the large project, which led to the discovery of the field particles W and Z ". The prize was given to Carlo Rubbia for his " idea to convert an existent large accelerator into a storage ring for protons and antiprotons", i.e. the conception of the SpS, and to Simon van der Meer for his " ingenious method for dense packing and storage of proton, now applied for antiprotons", i.e. devise of the technology enabling the Antiproton Accumulator — stochastic cooling. The conception, construction and operation of the SpS was considered a great technical achievement in itself.Before the SpS was commissioned, it was debated whether the machine would work at all, or if beam-beam effects on the bunched beams would prohibit an operation with high luminosity. The SpS proved that the beam-beam effect on bunched beams could be mastered, and that hadron colliders were excellent tools for experiments in particle physics. In such regard, it lay the ground work of LHC, the next generation hadron collider at CERN.