Transcranial direct-current stimulation


Transcranial direct current stimulation is a form of neuromodulation that uses constant, low direct current delivered via electrodes on the head. It was originally developed to help patients with brain injuries or psychiatric conditions like major depressive disorder. It can be contrasted with cranial electrotherapy stimulation, which generally uses alternating current the same way.
Research shows increasing evidence for tDCS as a treatment for depression. There is mixed evidence about whether tDCS is useful for cognitive enhancement in healthy people. There is no good evidence that tDCS is useful for memory deficits in Parkinson's disease and Alzheimer's disease, schizophrenia, non-neuropathic pain, or improving upper limb function after stroke.

tDCS efficacy in medical use

Depression

In 2015, the British National Institute for Health and Care Excellence found tDCS to be safe and to appear effective for depression treatment, although more and larger studies was needed at that point. Since then, several studies and meta-analysis have been conducted that add to the evidence of tDCS as a safe and effective treatment for depression.
A meta-analysis was published in 2020 summarising results across nine eligible studies, presenting moderate/high certainty of evidence. Active tDCS was significantly superior to sham for response, remission and depression improvement. According to a 2016 meta analysis published in the British Journal Psychology, 34% of tDCS-treated patients showed at least 50% symptom reduction across 6 randomised controlled trials.

Other medical use

Recent research on tDCS has shown promising results in treating other mental health conditions such as anxiety and PTSD. More research is required on the topic. There is also evidence that tDCS is useful in treating neuropathic pain after spinal cord injury and improving activities of daily living assessment after stroke.

tDCS safety - adverse effects and contraindications

According to the British National Institute for Health and Care Excellence, the evidence on tDCS for depression raises no major safety concerns.  
As of 2017, at stimulation up to 60 min and up to 4 mA over two weeks, adverse effects include skin irritation, a phosphene at the start of stimulation, nausea, headache, dizziness, and itching under the electrode. Typical treatment sessions lasting for about 20–30 minutes repeated daily for several weeks in the treatment of depression. Adverse effects of long term treatment were not known as of 2017. Nausea most commonly occurs when the electrodes are placed above the mastoid for stimulation of the vestibular system. A phosphene is a brief flash of light that can occur if an electrode is placed near the eye.
People susceptible to seizures, such as people with epilepsy should not receive tDCS. Studies have been completed to determine the current density at which overt brain damage occurs in rats. It was found that in cathodal stimulation, a current density of 142.9 A/m2 delivering a charge density of 52400 C/m2 or higher caused a brain lesion in the rat. This is over two orders of magnitude higher than protocols that were in use as of 2009.

Mechanism of action

tDCS stimulates and activates brain cells by delivering electrical signals. The way that the stimulation changes brain function is either by causing the neuron’s resting membrane potential to depolarize or hyperpolarize. When positive stimulation is delivered, the current causes a depolarization of the resting membrane potential, which increases neuronal excitability and allows for more spontaneous cell firing. When negative stimulation is delivered, the current causes a hyperpolarization of the resting membrane potential. This decreases neuron excitability due to the decreased spontaneous cell firing.
In case of treating depression, tDCS currents specifically target the left side of dorsolateral prefrontal cortex located in the frontal lobe. Left DLPFC has been shown to be associated with lower activity in the depressed population.
One of the aspects of tDCS is its ability to achieve cortical changes even after the stimulation is ended. The duration of this change depends on the length of stimulation as well as the intensity of stimulation. The effects of stimulation increase as the duration of stimulation increases or the strength of the current increases. tDCS has been proposed to promote both long term potentiation and long term depression, and further research is needed for validation.

Operation

Transcranial direct current stimulation works by sending constant, low direct current through the electrodes. When these electrodes are placed in the region of interest, the current induces intracerebral current flow. This current flow then either increases or decreases the neuronal excitability in the specific area being stimulated based on which type of stimulation is being used. This change of neuronal excitability leads to alteration of brain function, which can be used in various therapies as well as to provide more information about the functioning of the human brain.

Parts

Transcranial direct current stimulation is a relatively simple technique requiring only a few parts. These include two electrodes and a battery-powered device that delivers constant current. Control software can also be used in experiments that require multiple sessions with differing stimulation types so that neither the person receiving the stimulation nor the experimenter knows which type is being administered. Each device has an anodal, positively charged electrode and a cathodal, negative electrode. Current is "conventionally" described as flowing from the positive anode, through the intervening conducting tissue, to the cathode, creating a circuit. Note that in traditional electric circuits constructed from metal wires, current flow is created by the motion of negatively charged electrons, which actually flow from cathode to anode. However, in biological systems, such as the head, current is usually created by the flow of ions, which may be positively or negatively charged—positive ions will flow towards the cathode; negative ions will flow toward the anode. The device may control the current as well as the duration of stimulation.

Setup

To set up the tDCS device, the electrodes and the skin need to be prepared. This ensures a low resistance connection between the skin and the electrode. The careful placement of the electrodes is crucial to successful tDCS technique. The electrode pads come in various sizes with benefits to each size. A smaller sized electrode achieves a more focused stimulation of a site while a larger electrode ensures that the entirety of the region of interest is being stimulated. If the electrode is placed incorrectly, a different site or more sites than intended may be stimulated resulting in faulty results. One of the electrodes is placed over the region of interest and the other electrode, the reference electrode, is placed in another location in order to complete the circuit. This reference electrode is usually placed on the neck or shoulder of the opposite side of the body than the region of interest. Since the region of interest may be small, it is often useful to locate this region before placing the electrode by using a brain imaging technique such as fMRI or PET. Once the electrodes are placed correctly, the stimulation can be started. Many devices have a built-in capability that allows the current to be "ramped up" or increased gradually until the necessary current is reached. This decreases the amount of stimulation effects felt by the person receiving the tDCS. After the stimulation has been started, the current will continue for the amount of time set on the device and then will automatically be shut off. Recently a new approach has been introduced where instead of using two large pads, multiple smaller sized gel electrodes are used to target specific cortical structures. This new approach is called High Definition tDCS. In a pilot study, HD-tDCS was found to have greater and longer lasting motor cortex excitability changes than sponge tDCS.

Types of stimulation

There are three different types of stimulation: anodal, cathodal, and sham. The anodal stimulation is positive stimulation that increases the neuronal excitability of the area being stimulated. Cathodal stimulation decreases the neuronal excitability of the area being stimulated. Cathodal stimulation can treat psychiatric disorders that are caused by the hyper-activity of an area of the brain. Sham stimulation is used as a control in experiments. Sham stimulation emits a brief current but then remains off for the remainder of the stimulation time. With sham stimulation, the person receiving the tDCS does not know that they are not receiving prolonged stimulation. By comparing the results in subjects exposed to sham stimulation with the results of subjects exposed to anodal or cathodal stimulation, researchers can see how much of an effect is caused by the current stimulation, rather than by the placebo effect.

At-home administration of tDCS

Recently, tDCS devices are being researched and created intended for at-home use - ranging from treating medical conditions such as depression to enhancing general cognitive well-being.

History

The basic design of tDCS, using direct current to stimulate the area of interest, has existed for over 100 years. There were a number of rudimentary experiments completed before the 19th century using this technique that tested animal and human electricity. Luigi Galvani and Alessandro Volta were two such researchers that utilized the technology of tDCS in their explorations of the source of animal cell electricity. It was due to these initial studies that tDCS was first brought into the clinical scene. In 1801, Giovanni Aldini started a study in which he successfully used the technique of direct current stimulation to improve the mood of melancholy patients.
There was a brief rise of interest in transcranial direct current stimulation in the 1960s when studies by researcher D. J. Albert proved that the stimulation could affect brain function by changing the cortical excitability. He also discovered that positive and negative stimulation had different effects on the cortical excitability.. Research continued, further fueled by knowledge gained from other techniques like TMS and fMRI.

Comparison to other devices

In transcranial magnetic stimulation, an electric coil is held above the region of interest on the scalp that uses rapidly changing magnetic fields to induce small electrical currents in the brain. There are two types of TMS: repetitive TMS and single pulse TMS. Both are used in research therapy but effects lasting longer than the stimulation period are only observed in repetitive TMS. Similar to tDCS, an increase or decrease in neuronal activity can be achieved using this technique, but the method of how this is induced is very different. Transcranial direct current stimulation has the two different directions of current that cause the different effects. Increased neuronal activity is induced in repetitive TMS by using a higher frequency and decreased neuronal activity is induced by using a lower frequency.
Variants related to tDCS include tACS, tPCS and transcranial random noise stimulation, a group of technologies commonly referred to as transcranial electrical stimulation, or TES.

Research

tDCS and depression

Latest research on tDCS has shown increasing evidence for the treatment of depression.
A systematic review of placebo-controlled trials on tDCS was published recently in 2020. The meta-analysis collated results across nine eligible studies up until December 2018 to estimate odds ratio and number needed to treat of response and remission, and depression improvement. The results showed statistically superior efficacy of active tDCS compared to sham for Nine eligible studies, presenting moderate/high certainty of evidence, were included. Active tDCS was significantly superior to sham for response, remission and depression improvement.
Previously, a 2016 meta-analysis showed that 34% of tDCS-treated patients showed at least 50% symptom reduction. A 2017 study conducted by Brunoni showed 6-weeks of tDCS treatment resulted in reduction of at least half of depression symptoms in 41% of depressed people.
In 2015, the British National Institute for Health and Care Excellence found tDCS to be safe and to appear effective for depression treatment. Up until 2014, there have been several small randomized clinical trials in major depressive disorder ; most found alleviation of depressive symptoms. There have been only two RCTs in treatment-resistant MDD; both were small, and one found an effect and the other did not. One meta-analysis of the data focused on reduction in symptoms and found an effect compared to sham treatment, but another that was focused on relapse found no effect compared to sham.

tDCS beyond depression

In 2016, European meta analysis has found level B evidence for fibromyalgia, depression and craving.
There is mixed evidence about whether tDCS is useful for cognitive enhancement in healthy people. Several reviews have found evidence of small yet significant cognitive improvements. Other reviews found no evidence at all, although one of them has been criticized for overlooking within-subject effects and evidence from multiple-session tDCS trials. There is no good evidence that tDCS is useful for memory deficits in Parkinson's disease and Alzheimer's disease, schizophrenia, non-neuropathic pain, or improving upper limb function after stroke.
A 2015 review of results from hundreds of tDCS experiments found that there was no statistically conclusive evidence to support any net cognitive effect, positive or negative, of single session tDCS in healthy populations - there is no evidence that tDCS is useful for cognitive enhancement. A second study by the same authors found there was little-to-no statistically reliable impact of tDCS on any neurophysiologic outcome.
A few clinical trials have been conducted on the use of tDCS to ameliorate memory deficits in Parkinson's disease and Alzheimer's disease and healthy subjects, with mixed results. A 2016 Cochrane review found evidence that tDSC can improve activities of daily living in Parkinson’s disease but the evidence was very low to moderate quality.
Research conducted as of 2013 in schizophrenia, has found that while large effect sizes were initially found for symptom improvement, later and larger studies have found smaller effect sizes. Studies have mostly concentrated on positive symptoms like auditory hallucinations; research on negative symptoms is lacking. In addition to the tDCS research in depression, tDCS has been studied in reversing cognitive deficits in schizophrenia. Some researchers are investigating potential applications such as the improvement of focus and concentration. tDCS has also been studied in addiction.
Research conducted as of 2012 on the use of tDCS to treat pain, found that the research has been of low quality and cannot be used as a basis to recommend use of tDCS to treat pain. In chronic pain following spinal cord injury, research is of high quality and has found tDCS to be ineffective.
In stroke, research conducted as of 2014, has found that tDCS is not effective for improving upper limb function after stroke. While some reviews have suggested an effect of tDCS for improving post-stroke aphasia, a 2015 Cochrane review could find no improvement from combining tDCS with conventional treatment. Research conducted as of 2013 suggests that tDCS may be effective for improve vision deficits following stroke.
tDCS has also been used in neuroscience research, particularly to try to link specific brain regions to specific cognitive tasks or psychological phenomena. The cerebellum has been a focus of research, due to its high concentration of neurons, its location immediately below the skull, and its multiple reciprocal anatomical connections to motor and associative parts of the brain. Most such studies focus on the impact of cerebellar tDCS on motor, cognitive, and affective functions in healthy and patient populations, but some also employ tDCS over the cerebellum to study the functional connectivity of the cerebellum to other areas of the brain.

Regulatory approvals

tDCS is a CE approved treatment for Major Depressive Disorder in the UK, EU, Australia, and Mexico. As of 2015, tDCS has not been approved for any use by the US FDA. An FDA briefing document prepared in 2012 stated that "there is no regulation for therapeutic tDCS".