Electrical length


In telecommunications and electrical engineering, electrical length
refers to the length of an electrical conductor in terms of the phase shift introduced by transmission over that conductor at some frequency.

Use of the term

Depending on the specific context, the term "electrical length" is used rather than simple physical length to incorporate one or more of the following three concepts:
The first use of the term "electrical length" assumes a sine wave of some frequency, or at least a narrowband waveform centered around some frequency f. The sine wave will repeat with a period of T = . The frequency f will correspond to a particular wavelength λ along a particular conductor. For conductors which transmit signals at the speed of light c, the wavelength is given by λ = . A distance L along that conductor corresponds to N wavelengths where N; = .
In the figure at the right, the wave shown is seen to be N = 1.5 wavelengths long. A wave crest at the beginning of the graph, moving towards the right, will arrive at the end after a time 1.5 T . The electrical length of that segment is said to be "1.5 wavelengths" or, expressed as a phase angle, "540°" where N wavelengths corresponds to φ = 360°•N. In radio frequency applications, when a delay is introduced due to a transmission line, it is often the phase shift φ that is of importance, so specifying a design in terms of the phase or electrical length allows one to adapt that design to an arbitrary frequency by employing the wavelength λ applying to that frequency.

Velocity factor

In a transmission line, a signal travels at a rate controlled by the effective capacitance and inductance per unit of length of the transmission line. Some transmission lines consist only of bare conductors, in which case their signals propagate at the speed of light, c. More often the signal travels at a reduced velocity κc, where κ is the velocity factor, a number less than 1, representing the ratio of that velocity to the speed of light.
Most transmission lines contain a dielectric material filling some or all of the space in between the conductors. The relative permittivity or dielectric constant of that material increases the distributed capacitance in the cable, which reduces the velocity factor below unity. It is also possible for κ to be reduced due to a relative permeability of that material, which increases the distributed inductance, but this is almost never the case. Now, if one fills a space with a dielectric of relative permittivity, then the velocity of an electromagnetic plane wave is reduced by the velocity factor:
This reduced velocity factor would also apply to propagation of signals along wires immersed in a large space filled with that dielectric. However, with only part of the space around the conductors filled with that dielectric, there is less reduction of the wave velocity. Part of the electromagnetic wave surrounding each conductor "feels" the effect of the dielectric, and part is in free space. Then it is possible to define an effective relative permittivity which then predicts the velocity factor according to
is computed as a weighted average of the relative permittivity of free space and that of the dielectric:
where the fill factor F expresses the effective proportion of space so affected by the dielectric.
In the case of coaxial cable, where all of the volume in between the inner conductor and the shield is filled with a dielectric, the fill factor is unity, since the electromagnetic wave is confined to that region. In other types of cable, such as twin lead, the fill factor can be much smaller. Regardless, any cable intended for radio frequencies will have its velocity factor specified by the manufacturer. In the case of coaxial cable, where F=1, the velocity factor is solely determined by the sort of dielectric used as specified here.
For example, a typical velocity factor for coaxial cable is.66, corresponding to a dielectric constant of 2.25. Suppose we wish to send a 30 MHz signal down a short section of such a cable, and delay it by a quarter wave. In free space, this frequency corresponds to a wavelength of λ0=10m, so a delay of.25λ would require an electrical length of 2.5 m. Applying the velocity factor of.66, this results in a physical length of cable 1.67 m long.
The velocity factor likewise applies to antennas in cases where the antenna conductors are surrounded by a dieletric. This particularly applies to microstrip antennas such as the patch antenna. Waves on microstrip are affected mostly by the dielectric of the circuit board beneath them, but also on the air above them. Their velocity factors thus depend not directly on the permittivity of the circuit board material but on the effective permittivity which is often specified for a circuit board material. Note that the fill factor and therefore are somewhat dependent on the width of the trace compared to the thickness of the board.

Antennas

While there are certain wideband antenna designs, many antennas are classified as resonant and perform according to design around a particular frequency. This applies especially to broadcasting stations and communication systems which are confined to one frequency or narrow frequency band. This includes the dipole and monopole antennas and all of the designs based on them. In addition to the directive gain in beam antennas suffering away from the design frequency, the antenna feedpoint impedance is very sensitive to frequency offsets. Especially for transmitting, the antenna is often intended to operate at the resonant frequency. At the resonant frequency, by definition, that impedance is a pure resistance which matches the characteristic impedance of the transmission line and the output impedance of the transmitter. At frequencies away from the resonant frequency, the impedance includes some reactance. It is possible for an antenna tuner to be used to cancel that reactance, however that is often avoided as an extra complication.
The condition for resonance in a monopole antenna is for the element to be an odd multiple of a quarter-wavelength, λ/4. In a dipole antenna both driven conductors must be that long, for a total dipole length of λ/2.
The electrical length of an antenna element is, in general, different from its physical length
For example, increasing the diameter of the conductor, or the presence of nearby metal objects, will decrease the velocity of the waves in the element, increasing the electrical length.
An antenna which is shorter than its resonant length is described as "electrically short", and exhibits capacitive reactance. Similarly, an antenna which is longer than its resonant length is described as "electrically long" and exhibits inductive reactance.

Changing electrical length by loading

An antenna's effective electrical length can be changed without changing its physical length by adding reactance, in series with it. This is called lumped-impedance matching or loading.
For example, a monopole antenna such as a metal rod fed at one end, will be resonant when its electrical length is equal to a quarter wavelength, λ/4, of the frequency used. If the antenna is shorter than a quarter wavelength, the feedpoint impedance will include capacitive reactance; this causes reflections on the feedline and a mismatch at the transmitter or receiver, even if the resistive component of the impedance is correct. To cancel the capacitive reactance, an inductance, called a loading coil, is inserted in between the feedline and the antenna terminal. Selecting an inductance with the same reactance as the capacitative reactance seen at the antenna terminal, cancels that capacitance, and the antenna system will again be resonant. The feedline sees a purely resistive impedance. Since an antenna which had been too short now appears as if it were resonant, the addition of the loading coil is sometimes referred to as "electrically lengthening" the antenna.
Similarly, the feedpoint impedance of a monopole antenna longer than λ/4 will include inductive reactance. A capacitor in series with the antenna can cancel this reactance to make it resonant, which can be referred to as "electrically shortening" the antenna.
Inductive loading is widely used to reduce the length of whip antennas on portable radios such as walkie-talkies and short wave antennas on cars, to meet physical requirements.

Advantages

The electrical lengthening allows the construction of shorter aerials. It is applied in particular for aerials for VLF, longwave and medium-wave transmitters. Because those radio waves are several hundred meters to many kilometers long, mast radiators of the necessary height cannot be realised economically. It is also used widely for whip antennas on portable devices such as walkie-talkies to allow antennas much shorter than the standard quarter-wavelength to be used. The most widely used example is the rubber ducky antenna.

Disadvantages

The electrical lengthening reduces the bandwidth of the antenna if other phase control measures are not undertaken. An electrically extended aerial is less efficient than the equivalent, full-length antenna.

Technical realization

There are two possibilities for the realisation of the electric lengthening.
  1. switching in inductive coils in series with the aerial
  2. switching in metal surfaces, known as roof capacitance, at the aerial ends which form capacitors to earth.
Often both measures are combined. The coils switched in series must sometimes be placed in the middle of the aerial construction. The cabin installed at a height of 150-metres on the Blosenbergturm in Beromünster is such a construction, in which a lengthening coil is installed for the supply of the upper tower part

Application

Transmission aerials of transmitters working at frequencies below the longwave broadcasting band always apply electric lengthening. Broadcasting aerials of longwave broadcasting stations apply it often. However, for transmission aerials of NDBs electrical lengthening is extensively applied, because these use antennas which are considerably less tall than a quarter of the radiated wavelength.