Loading coil
A loading coil or load coil is an inductor that is inserted into an electronic circuit to increase its inductance. The term originated in the 19th century for inductors used to prevent signal distortion in long-distance telegraph transmission cables. The term is also used for inductors in radio antennas, or between the antenna and its feedline, to make an electrically short antenna resonant at its operating frequency.
The concept of loading coils was discovered by Oliver Heaviside in studying the problem of slow signalling speed of the first transatlantic telegraph cable in the 1860s. He concluded additional inductance was required to prevent amplitude and time delay distortion of the transmitted signal. The mathematical condition for distortion-free transmission is known as the Heaviside condition. Previous telegraph lines were overland or shorter and hence had less delay, and the need for extra inductance was not as great. Submarine communications cables are particularly subject to the problem, but early 20th century installations using balanced pairs were often continuously loaded with iron wire or tape rather than discretely with loading coils, which avoided the sealing problem.
Loading coils are historically also known as Pupin coils after Mihajlo Pupin, especially when used for the Heaviside condition and the process of inserting them is sometimes called pupinization.
Applications
Telephone lines
A common application of loading coils is to improve the voice-frequency amplitude response characteristics of the twisted balanced pairs in a telephone cable. Because twisted pair is a balanced format, half the loading coil must be inserted in each leg of the pair to maintain the balance. It is common for both these windings to be formed on the same core. This increases the flux linkages, without which the number of turns on the coil would need to be increased. Despite the use of common cores, such loading coils do not comprise transformers, as they do not provide coupling to other circuits.Loading coils inserted periodically in series with a pair of wires reduce the attenuation at the higher voice frequencies up to the cutoff frequency of the low-pass filter formed by the inductance of the coils and the distributed capacitance between the wires. Above the cutoff frequency, attenuation increases rapidly. The shorter the distance between the coils, the higher the cut-off frequency. The cutoff effect is an artifact of using lumped inductors. With loading methods using continuous distributed inductance there is no cutoff.
Without loading coils, the line response is dominated by the resistance and capacitance of the line with the attenuation gently increasing with frequency. With loading coils of exactly the right inductance, neither capacitance nor inductance dominate: the response is flat, waveforms are undistorted and the characteristic impedance is resistive up to the cutoff frequency. The coincidental formation of an audio frequency filter is also beneficial in that noise is reduced.
DSL
With loading coils, signal attenuation of a circuit remains low for signals within the passband of the transmission line but increases rapidly for frequencies above the audio cutoff frequency. If the telephone line is subsequently reused to support applications that require higher frequencies, such as in analog or digital carrier systems or digital subscriber line, loading coils must be removed or replaced. Using coils with parallel capacitors forms a filter with the topology of an m-derived filter and a band of frequencies above the cut-off is also passed. Without removal, for subscribers at an extended distance, e.g., over 4 miles from the central office, DSL cannot be supported.Carrier systems
American early and middle 20th century telephone cables had load coils at intervals of a mile, usually in coil cases holding many. The coils had to be removed to pass higher frequencies, but the coil cases provided convenient places for repeaters of digital T-carrier systems, which could then transmit a 1.5 Mbit/s signal that distance. Due to narrower streets and higher cost of copper, European cables had thinner wires and used closer spacing. Intervals of a kilometer allowed European systems to carry 2 Mbit/s.Radio antenna
Another type of loading coil is used in radio antennas. Monopole and dipole radio antennas are designed to act as resonators for radio waves; the power from the transmitter, applied to the antenna through the antenna's transmission line, excites standing waves of voltage and current in the antenna element. To be “naturally” resonant, the antenna must have a physical length of one quarter of the wavelength of the radio waves used. At resonance the antenna acts electrically as a pure resistance, absorbing all the power applied to it from the transmitter.In many cases for practical reasons it is necessary to make the antenna shorter than the resonant length, this is called an electrically short antenna. An antenna shorter than a quarter wavelength presents capacitive reactance to the transmission line. Some of the applied power is reflected back into the transmission line and travels back toward the transmitter. The two currents at the same frequency running in opposite directions causes standing waves on the transmission line, measured as a standing wave ratio greater than one. The elevated currents waste energy by heating the wire, and can even overheat the transmitter.
To make an electrically short antenna resonant, a loading coil is inserted in series with the antenna. The coil is built to have an inductive reactance equal and opposite to the capacitive reactance of the short antenna, so the combination of reactances cancels. When so loaded the antenna presents a pure resistance to the transmission line, preventing energy from being reflected. The loading coil is often placed at the base of the antenna, between it and the transmission line, but for more efficient radiation, it is sometimes inserted in the center of the antenna element itself.
Loading coils for powerful transmitters can have challenging design requirements, especially at low frequencies. The radiation resistance of short antennas can be very low, as low a few ohms in the LF or VLF bands, where antennas are commonly short and inductive loading is most needed. Because resistance in the coil winding is comparable to, or exceeds the radiation resistance, loading coils for extremely electrically short antennas must have extremely low AC resistance at the operating frequency. To reduce skin effect losses the coil is often made of tubing or Litz wire, with single layer windings, with turns spaced apart to reduce proximity effect resistance. They must often handle high voltages. To reduce power lost in dielectric losses, the coil is often suspended in air supported on thin ceramic strips. The capacitively loaded antennas used at low frequencies have extremely narrow bandwidths, and therefore if the frequency is changed the loading coil must be adjustable to tune the antenna to resonance with the new transmitter frequency. Variometers are often used.
Bulk power transmission
To reduce losses due to high capacitance on long-distance bulk power transmission lines, inductance can be introduced to the circuit with a flexible AC transmission system, a static VAR compensator, or a static synchronous series compensator. Series compensation can be thought of as an inductor connected to the circuit in series if it is supplying inductance to the circuit.Campbell equation
The Campbell equation is a relationship due to George Ashley Campbell for predicting the propagation constant of a loaded line. It is stated as;A more engineer friendly rule of thumb is that the approximate requirement for spacing loading coils is ten coils per wavelength of the maximum frequency being transmitted. This approximation can be arrived at by treating the loaded line as a constant k filter and applying image filter theory to it. From basic image filter theory the angular cutoff frequency and the characteristic impedance of a low-pass constant k filter are given by;
From these basic equations the necessary loading coil inductance and coil spacing can be found;
Expressing this in terms of number of coils per cutoff wavelength yields;
Since then
Campbell arrived at this expression by analogy with a mechanical line periodically loaded with weights described by Charles Godfrey in 1898 who obtained a similar result. Mechanical loaded lines of this sort were first studied by Joseph-Louis Lagrange.
The phenomenon of cutoff whereby frequencies above the cutoff frequency are not transmitted is an undesirable side effect of loading coils. Cutoff is avoided by the use of continuous loading since it arises from the lumped nature of the loading coils.
History
Oliver Heaviside
The origin of the loading coil can be found in the work of Oliver Heaviside on the theory of transmission lines. Heaviside represented the line as a network of infinitesimally small circuit elements. By applying his operational calculus to the analysis of this network he discovered what has become known as the Heaviside condition. This is the condition that must be fulfilled in order for a transmission line to be free from distortion. The Heaviside condition is that the series impedance, Z, must be proportional to the shunt admittance, Y, at all frequencies. In terms of the primary line coefficients the condition is:Heaviside was aware that this condition was not met in the practical telegraph cables in use in his day. In general, a real cable would have,
This is mainly due to the low value of leakage through the cable insulator, which is even more pronounced in modern cables which have better insulators than in Heaviside's day. In order to meet the condition, the choices are therefore to try to increase G or L or to decrease R or C. Decreasing R requires larger conductors. Copper was already in use in telegraph cables and this is the very best conductor available short of using silver. Decreasing R means using more copper and a more expensive cable. Decreasing C would also mean a larger cable. Increasing G is highly undesirable; while it would reduce distortion, it would at the same time increase the signal loss. Heaviside considered, but rejected, this possibility which left him with the strategy of increasing L as the way to reduce distortion.
Heaviside immediately proposed several methods of increasing the inductance, including spacing the conductors further apart and loading the insulator with iron dust. Finally, Heaviside made the proposal to use discrete inductors at intervals along the line. However, he never succeeded in persuading the British GPO to take up the idea. Brittain attributes this to Heaviside's failure to provide engineering details on the size and spacing of the coils for particular cable parameters. Heaviside's eccentric character and setting himself apart from the establishment may also have played a part in their ignoring of him.
John Stone
worked for the American Telephone & Telegraph Company and was the first to attempt to apply Heaviside's ideas to real telecommunications. Stone's idea was to use a bimetallic iron-copper cable which he had patented. This cable of Stone's would increase the line inductance due to the iron content and had the potential to meet the Heaviside condition. However, Stone left the company in 1899 and the idea was never implemented. Stone's cable was an example of continuous loading, a principle that was eventually put into practice is other forms, see for instance [|Krarup cable] later in this article.George Campbell
was another AT&T engineer working in their Boston facility. Campbell was tasked with continuing the investigation into Stone's bimetallic cable, but soon abandoned it in favour of the loading coil. His was an independent discovery, Campbell was aware of Heaviside's work in discovering the Heaviside condition, but unaware of Heaviside's suggestion of using loading coils to enable a line to meet it. The motivation for the change of direction was Campbell's limited budget.Campbell was struggling to set up a practical demonstration over a real telephone route with the budget he had been allocated. After considering that his artificial line simulators used lumped components rather than the distributed quantities found in a real line, he wondered if he could not insert the inductance with lumped components instead of using Stone's distributed line. When his calculations showed that the manholes on telephone routes were sufficiently close together to be able to insert the loading coils without the expense of either having to dig up the route or lay in new cables he changed to this new plan. The very first demonstration of loading coils on a telephone cable was on a 46-mile length of the so-called Pittsburgh cable on 6 September 1899 carried out by Campbell himself and his assistant. The first telephone cable using loaded lines put into public service was between Jamaica Plain and West Newton in Boston on 18 May 1900.
Campbell's work on loading coils provided the theoretical basis for his subsequent work on filters which proved to be so important for frequency-division multiplexing. The cut-off phenomena of loading coils, an undesirable side-effect, can be exploited to produce a desirable filter frequency response.
Michael Pupin
, inventor and Serbian immigrant to the USA, also played a part in the story of loading coils. Pupin filed a rival patent to the one of Campbell's. This patent of Pupin's dates from 1899. There is an earlier patent which is sometimes cited as Pupin's loading coil patent but is, in fact, something different. The confusion is easy to understand, Pupin himself claims that he first thought of the idea of loading coils while climbing a mountain in 1894, although there is nothing from him published at that time.Pupin's 1894 patent "loads" the line with capacitors rather than inductors, a scheme that has been criticised as being theoretically flawed and never put into practice. To add to the confusion, one variant of the capacitor scheme proposed by Pupin does indeed have coils. However, these are not intended to compensate the line in any way. They are there merely to restore DC continuity to the line so that it may be tested with standard equipment. Pupin states that the inductance is to be so large that it blocks all AC signals above 50 Hz. Consequently, only the capacitor is adding any significant impedance to the line and "the coils will not exercise any material influence on the results before noted".
Legal battle
Heaviside never patented his idea; indeed, he took no commercial advantage of any of his work. Despite the legal disputes surrounding this invention, it is unquestionable that Campbell was the first to actually construct a telephone circuit using loading coils. There also can be little doubt that Heaviside was the first to publish and many would dispute Pupin's priority.AT&T fought a legal battle with Pupin over his claim. Pupin was first to patent but Campbell had already conducted practical demonstrations before Pupin had even filed his patent. Campbell's delay in filing was due to the slow internal machinations of AT&T.
However, AT&T foolishly deleted from Campbell's proposed patent application all the tables and graphs detailing the exact value of inductance that would be required before the patent was submitted. Since Pupin's patent contained a formula, AT&T was open to claims of incomplete disclosure. Fearing that there was a risk that the battle would end with the invention being declared unpatentable due to Heaviside's prior publication, they decided to desist from the challenge and buy an option on Pupin's patent for a yearly fee so that AT&T would control both patents. By January 1901 Pupin had been paid $200,000 and by 1917, when the AT&T monopoly ended and payments ceased, he had received a total of $455,000.
Benefit to AT&T
The invention was of enormous value to AT&T. Telephone cables could now be used to twice the distance previously possible, or alternatively, a cable of half the previous quality could be used over the same distance. When considering whether to allow Campbell to go ahead with the demonstration, their engineers had estimated that they stood to save $700,000 in new installation costs in New York and New Jersey alone. It has been estimated that AT&T saved $100 million in the first quarter of the 20th century. Heaviside, who began it all, came away with nothing. He was offered a token payment but would not accept, wanting the credit for his work. He remarked ironically that if his prior publication had been admitted it would "interfere... with the flow of dollars in the proper direction...".Submarine cables
Distortion is a particular problem for submarine communication cables, partly because their great length allows more distortion to build up, but also because they are more susceptible to distortion than open wires on poles due to the characteristics of the insulating material. Different wavelengths of the signal travel at different velocities in the material causing dispersion. It was this problem on the first transatlantic telegraph cable that motivated Heaviside to study the problem and find the solution. Loading coils solve the dispersion problem, and the first use of them on a submarine cable was in 1906 by Siemens and Halske in a cable across Lake Constance.There are a number of difficulties using loading coils with heavy submarine cables. The bulge of the loading coils could not easily pass through the cable laying apparatus of cable ships and the ship had to slow down during the laying of a loading coil. Discontinuities where the coils were installed caused stresses in the cable during laying. Without great care, the cable might part and would be difficult to repair. A further problem was that the material science of the time had difficulties sealing the joint between coil and cable against ingress of seawater. When this occurred the cable was ruined. Continuous loading was developed to overcome these problems, which also has the benefit of not having a cutoff frequency.
Krarup cable
A Danish engineer, Carl Emil Krarup, invented a form of continuously loaded cable which solved the problems of discrete loading coils. Krarup cable has iron wires continuously wound around the central copper conductor with adjacent turns in contact with each other. This cable was the first use of continuous loading on any telecommunication cable. In 1902, Krarup both wrote his paper on this subject and saw the installation of the first cable between Helsingør and Helsingborg.Permalloy cable
Even though the Krarup cable added inductance to the line, this was insufficient to meet the Heaviside condition. AT&T searched for a better material with higher magnetic permeability. In 1914, Gustav Elmen discovered permalloy, a magnetic nickel-iron annealed alloy. In c. 1915, Oliver E. Buckley, H. D. Arnold, and Elmen, all at Bell Labs, greatly improved transmission speeds by suggesting a method of constructing submarine communications cable using permalloy tape wrapped around the copper conductors.The cable was tested in a trial in Bermuda in 1923. The first permalloy cable placed in service connected New York City and Horta in September 1924. Permalloy cable enabled signalling speed on submarine telegraph cables to be increased to 400 words/min at a time when 40 words/min was considered good. The first transatlantic cable achieved only two words/min.
Mu-metal cable
has similar magnetic properties to permalloy but the addition of copper to the alloy increases the ductility and allows the metal to be drawn into wire. Mu-metal cable is easier to construct than permalloy cable, the mu-metal being wound around the core copper conductor in much the same way as the iron wire in Krarup cable. A further advantage with mu-metal cable is that the construction lends itself to a variable loading profile whereby the loading is tapered towards the ends.Mu-metal was invented in 1923 by the Telegraph Construction and Maintenance Company, London, who made the cable, initially, for the Western Union Telegraph Co. Western Union were in competition with AT&T and the Western Electric Company who were using permalloy. The patent for permalloy was held by Western Electric which prevented Western Union from using it.