Vertical axis wind turbine


A vertical-axis wind turbines is a type of wind turbine where the main rotor shaft is set transverse to the wind while the main components are located at the base of the turbine. This arrangement allows the generator and gearbox to be located close to the ground, facilitating service and repair. VAWTs do not need to be pointed into the wind, which removes the need for wind-sensing and orientation mechanisms. Major drawbacks for the early designs included the significant torque variation or "ripple" during each revolution, and the large bending moments on the blades. Later designs addressed the torque ripple issue by sweeping the blades helically.
A vertical axis wind turbine has its axis perpendicular to the wind streamlines and vertical to the ground. A more general term that includes this option is "transverse axis wind turbine" or "cross-flow wind turbine." For example, the original Darrieus patent, US Patent 1835018, includes both options.
Drag-type VAWTs such as the Savonius rotor typically operate at lower tipspeed ratios than lift-based VAWTs such as Darrieus rotors and cycloturbines.

General aerodynamics

The forces and the velocities acting in a Darrieus turbine are depicted in figure 1. The resultant velocity vector,, is the vectorial sum of the undisturbed upstream air velocity,, and the velocity vector of the advancing blade,.
Thus the oncoming fluid velocity varies during each cycle. Maximum velocity is found for and the minimum is found for, where is the azimuthal or orbital blade position. The angle of attack,, is the angle between the oncoming air speed, W, and the blade's chord. The resultant airflow creates a varying, positive angle of attack to the blade in the upstream zone of the machine, switching sign in the downstream zone of the machine.
It follows from geometric considerations of angular velocity as seen in the accompanying figure that:
and:
Solving for the relative velocity as the resultant of the tangential and normal components yields:
Thus, combining the above with the definitions for the tip speed ratio yields the following expression for the resultant velocity:
Angle of attack is solved as:
Which when substituting the above yields:
The resultant aerodynamic force is resolved either into lift - drag components or normal - tangential components. The forces are considered acting at the quarter-chord point, and the pitching moment is determined to resolve the aerodynamic forces. The aeronautical terms "lift" and "drag" refer to the forces across and along the approaching net relative airflow. The tangential force acts along the blade's velocity, pulling the blade around, and the normal force acts radially, pushing against the shaft bearings. The lift and the drag force are useful when dealing with the aerodynamic forces around the blade such as dynamic stall, boundary layer etc.; while when dealing with global performance, fatigue loads, etc., it is more convenient to have a normal-tangential frame. The lift and the drag coefficients are usually normalised by the dynamic pressure of the relative airflow, while the normal and tangential coefficients are usually normalised by the dynamic pressure of undisturbed upstream fluid velocity.
A = Blade Area,
R = Radius of turbine
The amount of power, P, that can be absorbed by a wind turbine:
Where is the power coefficient, is air density, is the swept area of the turbine, and is the wind speed.

Advantages

VAWTs offer a number of advantages over traditional horizontal-axis wind turbines :

One of the major outstanding challenges facing vertical axis wind turbine technology is dynamic stall of the blades as the angle of attack varies rapidly.
The blades of a VAWT are fatigue-prone due to the wide variation in applied forces during each rotation. This can be overcome by the use of modern composite materials and improvements in design - including the use of aerodynamic wing tips that cause the spreader wing connections to have a static load. The vertically oriented blades can twist and bend during each turn, causing them to break apart.
VAWTs have proven less reliable than HAWTs, although modern designs of VAWTs have overcome many of the issues associated with early designs.

Applications

The Windspire, a small VAWT intended for individual use was developed in the early 2000s by US company Mariah Power. The company reported that several units had been installed across the US by June 2008.
Arborwind, an Ann-Arbor based company, produces a patented small VAWT which has been installed at several US locations as of 2013.
In 2011, Sandia National Laboratories wind-energy researchers began a five-year study of applying VAWT design technology to offshore wind farms. The researchers stated: "The economics of offshore windpower are different from land-based turbines, due to installation and operational challenges. VAWTs offer three big advantages that could reduce the cost of wind energy: a lower turbine center of gravity; reduced machine complexity; and better scalability to very large sizes. A lower center of gravity means improved stability afloat and lower gravitational fatigue loads. Additionally, the drivetrain on a VAWT is at or near the surface, potentially making maintenance easier and less time-consuming. Fewer parts, lower fatigue loads and simpler maintenance all lead to reduced maintenance costs."
A 24-unit VAWT demonstration plot was installed in southern California in the early 2010s by Caltech aeronautical professor John Dabiri. His design was incorporated in a 10-unit generating farm
installed in 2013 in the Alaskan village of Igiugig.
Dulas, Anglesey received permission in March 2014 to install a prototype VAWT on the breakwater at Port Talbot waterside. The turbine is a new design, supplied by Wales-based C-FEC, and will be operated for a two-year trial. This VAWT incorporates a wind shield which blocks the wind from the advancing blades, and thus requires a wind-direction sensor and a positioning mechanism, as opposed to the "egg-beater" types of VAWTs discussed above.
4 Navitas have been operating two prototype VAWTs since June 2013, powered by a Siemens Power Train, they are due to enter the market in January 2015, with a free technology share to interested parties. 4 Navitas are now in the process of scaling their prototype to 1 MW, and then floating the turbine on an offshore pontoon. This will reduce the cost of offshore wind energy.
The Dynasphere, is Michael Reynolds' 4th generation vertical axis windmill. These windmills have two 1.5 KW generators and can produce electricity at very low speeds.