Catalyst 6500


The Catalyst 6500 is a modular chassis network switch manufactured by Cisco Systems since 1999, capable of delivering speeds of up to "400 million packets per second".
A 6500 comprises a chassis, power supplies, one or two supervisors, line cards and service modules. A chassis can have 3, 4, 6, 9 or 13 slots each with the option of one or two modular power supplies. The supervisor engine provides centralised forwarding information and processing; up to two of these cards can be installed in a chassis to provide active/standby or stateful failover. The line cards provide port connectivity and service modules to allow for devices such as firewalls to be integrated within the switch.

Supervisor

The 6500 Supervisor comprises a Multilayer Switch Feature Card and a Policy Feature Card. The MSFC runs all software processes, such as routing protocols. The PFC makes forwarding decisions in hardware.
The supervisor has connections to the switching fabric and classic bus, as well as bootflash for the Cisco IOS software.
The latest generation supervisor is the Supervisor 2T.
This supervisor was introduced at Cisco Live Las Vegas in July 2011.
It provides 80 gigabits per slot on all slots of 6500-E chassis.

Operating systems

The 6500 currently supports three operating systems: CatOS, Native IOS and Modular IOS.

CatOS

is supported for layer 2 operations only. To be able to perform routing functions operations, the switch must be run in hybrid mode. In this case, CatOS runs on the Switch Processor portion of the Supervisor, and IOS runs on the Route Processor also known as the MSFC. To make configuration changes, the user must then manually switch between the two environments.
CatOS does have some functionality missing and is generally considered 'obsolete' compared to running a switch in Native Mode.

Native IOS

can be run on both the SP and RP. In this instance, the user is unaware of where a command is being executed on the switch, even though technically two IOS images are loaded—one on each processor. This mode is the default shipping mode for Cisco products and enjoys support of all new features and line cards.

Modular IOS

Modular IOS is a version of Cisco IOS that employs a modern UNIX-based kernel to overcome some of the limitations of IOS. Additional to this is the ability to perform patching of processes without rebooting the device and in service upgrades.

Methods of operation

The 6500 has five major modes of operation: Classic, cef256, dcef256, cef720 and dcef720.

Classic Bus

The 6500 classic architecture provides 32 Gbit/s centralised forwarding performance. The design is such that an incoming packet is first queued on the line card and then placed on to the global data bus and is copied to all other line cards, including the supervisor. The supervisor then looks up the correct egress port, access lists, policing and any relevant rewrite information on the PFC. This is placed on the result bus and sent to all line cards. Those line cards for whom the data is not required terminate processing. The others continue forwarding and apply relevant egress queuing.
The speed of the classic bus is 32gb half duplex and is the only supported way of connecting a Supervisor 32 engine to a 6500.

cef256

This method of forwarding was first introduced with the Supervisor 2 engine. When used in combination with a switch fabric module, each line card has an 8Gbit/s connection to the switch fabric and additionally a connection to the classic bus. In this mode, assuming all line cards have a switch fabric connection, an ingress packet is queued as before and its headers are sent along the dBus to the supervisor. They are looked up in the PFC and then the result is placed on the rBus. The initial egress line card takes this information and forwards the data to the correct line card along the switch fabric. The main advantage here is that there is a dedicated 8 Gbit/s connection between the line cards. The receiving line card queues the egress packet before sending it from the desired port.
The '256' is derived from a chassis using 2x8gb ports on 8 slots of a 6509 chassis: 16 * 8 = 128, 128 * 2 = 256. The number is doubled because of the switch fabric being 'full duplex'.

dcef256

dcef256 uses distributed forwarding. These line cards have 2x8gb connections to the switch fabric and no classic bus connection. Only modules that have a DFC can use dcef.
Unlike the previous examples, the line cards hold a full copy of the supervisor's routing tables locally, as well as its own L2 adjacency table. This eliminates the need for any connection to the classic bus or requirement to use the shared resource of the supervisor. In this instance, an ingress packet is queued, but its destination looked up locally. The packet is then sent across the switch fabric, queued in the egress line card before being sent.

cef720

This mode of operation acts identically to cef256, except with 2x20gb connections to the switch fabric and there is no need for a switch fabric module. This was first introduced into the Supervisor Engine 720.
The '720' is derived from a chassis using 2x20gb ports on 9 slots of a 6509 chassis. 40 * 9 = 360 * 2 = 720. The number is doubled to the switch fabric being 'full duplex'. The reason 9 slots are used for the calculation instead of 8 for the cef256 is that it no longer needs to waste a slot with the switch fabric module.

dcef720

This mode of operation acts identically to dcef256, except with 2x20gb connections to the switch fabric.

Power supplies

The 6500 is able to deliver high densities of Power over Ethernet across the chassis. Because of this, power supplies are a key element of configuration.

Chassis support

The following goes through the various 6500 chassis and their supported power supplies and loads.

6503

The original chassis permits up to 2800W and uses rear-inserted power supplies different from the others in the series.

6504-E

This chassis permits up to 5000W of power and, like the 6503, uses rear-inserted power supplies.

6506, 6509, 6506-E and 6509-E

The original chassis can support up to a maximum of 4000W of power, because of backplane limitations. If a power supply above this is inserted, it will deliver at full power up to this limitation.
The 6509-NEB-A supports a maximum of 4500W.
With the introduction of the 6506-E and 6509-E series chassis, the maximum power supported has been increased to in excess of 14500 W.

6513

This chassis can support a maximum of 8000W. However, to obtain this, it must be run in combined mode. Therefore, it is suggested that it be run in redundant mode to obtain a maximum of 6000W.

Power redundancy options

The 6500 supports dual power supplies for redundancy. These may be run in one of two modes: redundant or combined mode.

Redundant mode

When running in Redundant mode, each power supply provides approximately 50% of its capacity to the chassis. In the event of a failure, the unaffected power supply will then provide 100% of its capacity and an alert will be generated. As there was enough to power the chassis ahead of time, there is no interruption to service in this configuration. This is also the default and recommended way to configure power supplies.

Combined mode

In combined mode, each power supply provides approximately 83% of its capacity to the chassis. This allows for greater utilisation of the power supplies and potentially increased PoE densities.
In systems that are equipped with two power supplies, if one power supply fails and the other power supply cannot fully power all of the installed modules, system power management will shut down devices in the following order:
This shut down order is fixed and cannot be changed.

Online Insertion & Removal

OIR is a feature of the 6500 which allows hot swapping most line cards without first powering down the chassis. The advantage of this is that one may perform an in-service upgrade. However, before attempting this, it is important to understand the process of OIR and how it may still require a reload.
To prevent bus errors, the chassis has three pins in each slot which correspond with the line card. Upon insertion, the longest of these makes first contact and stalls the bus. As the line card is pushed in further, the middle pin makes the data connection. Finally, the shortest pin removes the bus stall and allows the chassis to continue operation.
However, if any part of this operation is skipped, errors will occur. Common problems include: